1. POST Error Message
Scalable Modular Server DX2000 Maintenance Guide
119
Chapter 3 Appendix
(4/4)
Error Message
Cause
Solution
C11F
Backup Data of BMC
Mezzanine card has
corrupted.
BMC Mezzanine card has corrupted.
Contact a maintenance service
company.
C120
BMC Runtime FW corrupted.
Failure in starting BMC FW
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C121
BMC Force Update FW
corrupted.
Failure in starting BMC FW
C122
BMC Configuration area
corrupted.
BMC configuration area corrupted.
C123
BMC eMMC inaccessible.
Initialization failed due to access error
to BMC internal flash memory.
C125
BMC eMMC mode error.
An operating mode error of the BMC
internal flash memory was detected.
C126
BMC eMMC partition
corrupted.
A partition error of the BMC internal
flash memory was detected.
C127
BMC eMMC format
corrupted.
A format error of the BMC internal
flash memory was detected.
C128
BMC is in Update Mode.
BMC is in a firmware update mode.
C300
Out - of - band setup
configuration failure
Access to the BMC Mezzanine card
failed.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C302 Hardware
configuration
error.
The hardware configuration of this
server is incorrect.
Contact a maintenance service
company.
C501
ME is in Recovery Mode.
Intel Node Manager is in Recovery
Mode.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C624
Invalid internal BIOS
Configuration Data.
An internal error of BIOS
Configuration Data was detected.
C625
BIOS Configuration Data
Send Error.
Transmission error of BIOS
Configuration Data
C626
BIOS Configuration Data
Read Error.
Read error of BIOS Configuration
Data
C627
BIOS Configuration Data
Write Error.
Write error of BIOS Configuration Data
C628 System
configuration data
cleared by System Boot
Options command.
SETUP configuration was cleared by
the standard command of Set System
Boot Options compliant with IPMI.
Start SETUP and set each item again. If
the problem persists, contact a
maintenance service company.