6. System Diagnostic Tool
Scalable Modular Server DX2000 Maintenance Guide
47
Chapter 1 Maintenance
smart
Function: Displays the s.m.a.r.t information of server modules.
You can execute this command only for the server module whose Type is ”TeDoLi”.
Argument:
Description
arg1
cpu board
Specify the server module to display the s.m.a.r.t information.
all
Specify all server modules of this server.
x
Specify the server module number.
You can specify multiple server modules.
Example)
“
1 6-23 36
”→
Server modules 1, 6 to 23 and, 36 are specified.
Screen image:
Descripti
on number
MNG PC> smart 6
<ENTER>
<CPU Board 6>
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-358.14.1.el6.x86_64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG MZNLN128HCGR-00000
Serial Number: S1ZXNXAG603879
LU WWN Device Id: 5 002538 d401eb1a7
Firmware Version: EMT2100Q
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4c
Local Time is: Tue Dec 15 10:24:28 2015 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00)
Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
:
:
Содержание DX2000
Страница 131: ... MEMO ...