3. Error Messages of CSC Modules
Scalable Modular Server DX2000 Maintenance Guide
127
Chapter 3 Appendix
3.
Error Messages of CSC Modules
You can check error messages on the virtual LCD displayed in the Web browser of EXPRESSSCOPE engine 3.
The table below shows error messages, meaning and actions.
(1/3)
LCD display message
Cause
Solution
Power Supply AC Lost
The AC cable of PSU3 is
not connected.
Check if the AC cable is connected. If
you find it correctly connected and find
the problem, contact a maintenance
service company.
Power Supply2 AC Lost
The AC cable of PSU2 is
not connected.
Power Supply1 AC Lost
The AC cable of PSU1 is
not connected.
Power Supply2 Predictive Failure detected
PSU2 failed.
Replace PSU.
Contact a maintenance service
company.
Power Supply1 Predictive Failure detected
PSU1 failed.
Power Supply Predictive Failure detected
PSU3 or PSU DC failed.
System FAN8 Lower Non-Critical
The rotating speed of
FAN8 is lower than the
threshold.
Replace the fan.
Contact a maintenance service
company.
System FAN7 Lower Non-Critical
The rotating speed of
FAN7 is lower than the
threshold.
System FAN6 Lower Non-Critical
The rotating speed of
FAN6 is lower than the
threshold.
System FAN5 Lower Non-Critical
The rotating speed of
FAN5 is lower than the
threshold.
System FAN4 Lower Non-Critical
The rotating speed of
FAN4 is lower than the
threshold.
System FAN3 Lower Non-Critical
The rotating speed of
FAN3 is lower than the
threshold.
System FAN2 Lower Non-Critical
The rotating speed of
FAN2 is lower than the
threshold.
System FAN1 Lower Non-Critical
The rotating speed of
FAN1 is lower than the
threshold.
Power Supply2 Failure detected
PSU2 failed.
Replace the PSU.
Contact a maintenance service
company.
Power Supply1 Failure detected
PSU1 failed.
Power Supply Failure detected
PSU3 or PSU DC failed.
Power Supply2 Temperature Lower
Non-Critical
The temperature of PSU2
is lower than the threshold.
Check the environment temperature. If
you find no problem, replace the PSU.
Contact a maintenance service
company.
Power Supply1 Temperature Lower
Non-Critical
The temperature of PSU1
is lower than the threshold.
Power Supply Temperature Lower
Non-Critical
The temperature of PSU3
is lower than the threshold.
Power Supply2 Temperature Upper
Non-Critical
The temperature of PSU2
is lower than the threshold.
Check the environment temperature and
the dust in the chassis. If you clean it and
find the problem, replace the PSU.
Contact a maintenance service
company.
Power Supply1 Temperature Upper
Non-Critical
The temperature of PSU1
is lower than the threshold.
Power Supply Temperature Upper
Non-Critical
The temperature of PSU3
is lower than the threshold.
Baseboard Temperature2 Lower Non-Critical
The sensor on the
baseboard detected the
temperature below the
threshold.
Check the environment temperature and
find no problem, replace the chassis.
Contact a maintenance service
company.
Baseboard Temperature1 Lower Non-Critical
The sensor on the
baseboard detected the
temperature below the
threshold.
Baseboard Temperature Lower Non-Critical
The sensor on the
baseboard detected the
temperature below the
threshold.