2. BMC Error Messages
Scalable Modular Server DX2000 Maintenance Guide
123
Chapter 3 Appendix
(1) BMC error messages for the server
(1/2)
BMC messages displayed on the bottom of LCD
Cause
Solution
Processor Voltage Lower Non-Critical
Voltage error detected
Contact a maintenance service company.
Processor Voltage Upper Non-Critical
Processor Voltage Lower Critical
Processor Voltage Upper Critical
BaseBoard Voltage Lower Non-Critical
BaseBoard Voltage Upper Non-Critical
BaseBoard Voltage Lower Critical
BaseBoard Voltage Upper Critical
VBAT Lower Non-Critical
VBAT Upper Non-Critical
VBAT Lower Critical
VBAT Upper Critical
Baseboard Temperature1 Lower Non-Critical
Temperature error
detected
The fan may be faulty or clogged. Contact
a maintenance service company.
Baseboard Temperature1 Upper Non-Critical
Baseboard Temperature1 Lower Critical
Baseboard Temperature1 Upper Critical
Ambient Temperature Lower Non-Critical
Ambient Temperature Upper Non-Critical
Ambient Temperature Lower Critical
Ambient Temperature Upper Critical
DIMM Area Temperature Lower Non-Critical
DIMM Area Temperature Upper Non-Critical
DIMM Area Temperature Lower Critical
DIMM Area Temperature Upper Critical
Processor Thermal Control Upper
Non-Critical
Processor Thermal Control Upper Critical
DUMP Request !
The dump button was
pressed.
Wait until the memory dump finishes.
Processor Thermal Trip
The power was forcibly
turned off due to the
abnormal temperature of
CPU.
Contact a maintenance service company.
DIMM1 Uncorrectable Error
An uncorrectable error was
detected in memory 1.
DIMM2 Uncorrectable Error
An uncorrectable error was
detected in memory 2.
DIMM3 Uncorrectable Error
An uncorrectable error was
detected in memory 3.
DIMM4 Uncorrectable Error
An uncorrectable error was
detected in memory 4.
Processor Internal Error
An internal error (IERR) of
CPU was detected.
Содержание DX2000
Страница 131: ... MEMO ...