1. POST Error Message
Scalable Modular Server DX2000 Maintenance Guide
117
Chapter 3 Appendix
(2/4)
Error Message
Cause
Solution
A800 Memory
not
detected
Available memory is not implemented. Contact a maintenance service
company.
A804
Latest memory module is
corrupted.
The system flash memory is
corrupted.
AE01
DIMM1 has been disabled.
A memory error was detected.
DIMM1 is disabled.
AE02
DIMM2 has been disabled.
A memory error was detected.
DIMM2
is disabled.
AE03
DIMM3 has been disabled.
A memory error was detected. DIMM3
is disabled.
AE04
DIMM4 has been disabled.
A memory error was detected. DIMM4
is disabled.
AE81
DIMM1 with error is
enabled.
A memory error was detected in
DIMM1. As all memories are disabled,
it was forcibly enabled.
AE82
DIMM2 with error is
enabled.
A memory error was detected in
DIMM2. As all memories are disabled,
it was forcibly enabled.
AE83
DIMM3 with error is
enabled.
A memory error was detected in
DIMM3. As all memories are disabled,
it was forcibly enabled.
AE84
DIMM4 with error is
enabled.
A memory error was detected in
DIMM4. As all memories are disabled,
it was forcibly enabled.
B000 Expansion
ROM
not
initialized
Failed to expand option ROM.
Disable option ROM expansion for the
option board on which OS is not started.
Start SETUP and disable[PCI
Configuration] - [PCI Device Controller
and Option ROM Settings] - [PCIxx Slot
Option ROM] in the Advanced menu. (xx:
PCI slot number)
B001 Expansion
ROM
not
initialized - PCI
Slot 1
Option ROM expansion in PCI slot 1
failed.
B030
PCI System Error on
Bus/Device/Function
PCI SERR was detected.
Contact a maintenance service
company.
B040
PCI Parity Error on
Bus/Device/Function
PCI PERR was detected.
B211
PCI Slot 1 - PCIe Link
Failure
Connection failure of PCIe bus was
detected on PCI slot 1.
B231
PCI Slot 1 - PCIe Link
Width Error
A Link Width error was detected in PCI
Slot 1.
B271
PCI Slot 1 - PCIe Link
Speed Error
Link Speed error was detected on PCI
Slot 1.
B800 DXE_PCI_BUS_OUT_OF_RESOU
RCES
Resources to be allocated to PCI
expansion card was insufficient.
C020
The error occurred during
voltage sensor reading.
The voltage sensor caused a read
error.
C021
System Voltage out of the
range.
A voltage trouble was detected.
C040
SROM data read error
FRU caused a data read error.
Содержание DX2000
Страница 131: ... MEMO ...