1. POST Error Message
Scalable Modular Server DX2000 Maintenance Guide
118
Chapter 3 Appendix
(3/4)
Error Message
Cause
Solution
C061
1st SMBus device Error
detected.
An error was detected in 1st SM Bus. Contact a maintenance service company.
C062
2nd SMBus device Error
detected.
An error was detected in 2nd SM Bus.
C063
3rd SMBus device Error
detected.
An error was detected in 3rd SM Bus.
C064
4th SMBus device Error
detected.
An error was detected in 4th SM Bus
C065
5th SMBus device Error
detected.
An error was detected in 5th SM Bus.
C066
6th SMBus device Error
detected.
An error was detected in 6th SM Bus.
C067
7th SMBus device Error
detected.
An error was detected in 7th SM Bus.
C068
8th SMBus device Error
detected.
An error was detected in 8th SM Bus.
C101
BMC Memory Test
Failed..
BMC device (chip) error.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C102
BMC Firmware Code
Area CRC check
Failed.
C103
BMC core hardware
failure.
C104
BMC IBF or OBF check
failed.
Accessing the BMC address failed.
C105
BMC SEL area full.
The area to save the system event log
is full.
Erase the event log as needed.
C10C
BMC update firmware
corrupted.
BMC firmware update corrupted.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C10D
Internal Use Area of BMC
FRU corrupted.
FRU storing device information
corrupted.
C10E
BMC SDR Repository empty.
An error was detected in SDR of BMC.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
FRU storing device information
corrupted.
C111
BMC SDR Repository
failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
BMC SEL device failure
C113
BMC RAM test error.
BMC RAM error was detected.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
C115 Management
controller
not responding
Management controller does not
respond.
Update the BMC firmware. If you find the
same error continually detected, contact
a maintenance service company.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was detected.
C119
SDR repository corrupt.
BMC error or SDR data error was
detected.
C11A SEL
corrupt.
BMC error or System event log error
was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not found.
Contact a maintenance service
company.
C11C BMC
Mezzanine
partition
is invalid.
BMC Mezzanine card format is invalid.
C11D BMC
is in Forced Boot Mode.
Detected that BMC is in Forced Boot
Mode.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.
C11E Communication
with
BMC
was failed in previous
boot
Communication with BMC failed in the
previous boot.
Remove the server module, wait for 30
seconds, implement it again and start it.
If you find the same error continually
detected, contact a maintenance service
company.