CHAPTER 15 SERIAL INTERFACE UART6
Preliminary User’s Manual U17260EJ3V1UD
349
Figure 15-2. LIN Reception Operation
LIN Bus
13-bit
SBF reception
SF
reception
ID
reception
Data
reception
Data
reception
Data
reception
Wakeup
signal frame
Sync
break field
Sync field
Identifier
field
Data field
Data field
Checksum
field
R
X
D6
(input)
Reception interrupt
(INTSR6)
Edge detection
(INTP0)
Capture timer
Disable
Enable
Disable
Enable
<1>
<2>
<3>
<4>
<5>
Reception processing is as follows.
<1> The wakeup signal is detected at the edge of the pin, and enables UART6 and sets the SBF reception
mode.
<2> Reception continues until the STOP bit is detected. When an SBF with low-level data of 11 bits or more has
been detected, it is assumed that SBF reception has been completed correctly, and an interrupt signal is
output. If an SBF with low-level data of less than 11 bits has been detected, it is assumed that an SBF
reception error has occurred. The interrupt signal is not output and the SBF reception mode is restored.
<3> If SBF reception has been completed correctly, an interrupt signal is output. Start 16-bit timer/event counter
00 by the SBF reception end interrupt servicing and measure the bit interval (pulse width) of the sync field
(see
7.4.8 Pulse width measurement operation
). Detection of errors OVE6, PE6, and FE6 is
suppressed, and error detection processing of UART communication and data transfer of the shift register
and RXB6 is not performed. The shift register holds the reset value FFH.
<4> Calculate the baud rate error from the bit interval of the sync field, disable UART6 after SF reception, and
then re-set baud rate generator control register 6 (BRGC6).
<5> Distinguish the checksum field by software. Also perform processing by software to initialize UART6 after
reception of the checksum field and to set the SBF reception mode again.
Figure 15-3 shows the port configuration for LIN reception operation.
The wakeup signal transmitted from the LIN master is received by detecting the edge of the external interrupt
(INTP0). The length of the sync field transmitted from the LIN master can be measured using the external event
capture operation of 16-bit timer/event counter 00, and the baud rate error can be calculated.
The input source of the reception port input (R
X
D6) can be input to the external interrupt (INTP0) and 16-bit
timer/event counter 00 by port input switch control (ISC0/ISC1), without connecting R
X