CHAPTER 11 WATCHDOG TIMER
Preliminary User’s Manual U17260EJ3V1UD
299
Remark
If the overflow time is set to 2
10
/f
RL
, the window close time and open time are as follows.
Setting of Window Open Period
25% 50% 75% 100%
Window close time
0 to 3.56 ms
0 to 2.37 ms
0 to 0.119 ms
None
Window open time
3.56 to 3.88 ms
2.37 to 3.88 ms
0.119 to 3.88 ms
0 to 3.88 ms
<When window open period is 25%>
•
Overflow time:
2
10
/f
RL
(MAX.) = 2
10
/264 kHz (MAX.) = 3.88 ms
•
Window close time:
0 to 2
10
/f
RL
(MIN.)
×
(1
−
0.25) = 0 to 2
10
/216 kHz (MIN.)
×
0.75 = 0 to 3.56 ms
•
Window open time:
2
10
/f
RL
(MIN.)
×
(1
−
0.25) to 2
10
/f
RL
(MAX.)
= 2
10
/216 kHz (MIN.)
×
0.75 to 2
10
/264 kHz (MAX.)
= 3.56 to 3.88 ms