3. Data Entry Screens are used to specify prescription parameters.
Sample of a Data Entry Screen
In the above example, the cursor rests on a field requiring numeric data entry for specific
prescription information, e.g., the volume in the IV bag. The operator enters the correct
information using the numeric keys and decimal point key. When the correct data is displayed
and the YES/ENTER key is pressed, the pump accepts the selection if it is a valid entry value and
moves the cursor down to the next field. If the down arrow key is used to move to the next field,
the value reverts back to default or the last programmed value.
4. Running Screens display information to the operator about the progress of the specific infusion
while the pump is running:
Sample of a Running Screen
The standard running screen displays the Mode Identifier, the rate of pumping, a graphical bar
that indicates the progress of the infusion, the volume already infused, and the time remaining for
the infusion. No action is required on a run screen, therefore, no highlight bar appears. In some
therapies a field may toggle to give the operator more information, i.e. the REMAIN field may
change from
HH:MM
(time remaining) to
mL
to tell you how much volume is remaining as well.
The information on the run screen will alternate between a four-line display and a large font display
of each line of information on the screen.
5. User Notification Screens are messages displayed to the user for information.
Sample of User Notification Screen
Words representing keys are displayed in reverse video (shown in this manual as bold text and/or
capitalized). The action requested by a notification screen is either to press a specified key or to
resolve an alert, alarm, or error code.
For all events such as alerts, alarms, or error codes, specific notification screens will also be displayed.
(See chapter entitled “Troubleshooting” for specific alert, alarm, and error code messages and how
to resolve them.) The audio alarm also beeps and the LEDs blink whenever an alarm or error code
occurs. In the event of an error code, user directions will be
Содержание CURLIN INFUSION PainSmart
Страница 24: ...21 Figure 2 8 Closing the Pump Door Pump Set Features...
Страница 39: ......
Страница 49: ......
Страница 113: ......
Страница 121: ......
Страница 125: ...118...
Страница 126: ...119 Technical Specifications...
Страница 127: ...120...
Страница 128: ...121 Technical Specifications...
Страница 129: ...122...
Страница 130: ...123 T...
Страница 131: ...124...
Страница 137: ......
Страница 139: ......
Страница 140: ......
Страница 141: ...Rev I 360 9043...