7
•
Retention of programmed infusion settings until cleared by the clinician, thus eliminating
the need to reprogram before each use.
•
Mandatory requirement of two independent key press actions before a running pump can be
turned off, thus minimizing the accidental interruption of a therapy in progress.
•
Powered by two readily available, cost-effective C-cell alkaline batteries.
•
Attractive yet robust design that is impact resistant and water resistant.
•
Audio alarms that can be adjusted from 1 (very quiet) to 9 (loudest) to meet specific patient
and clinical setting needs but that cannot be totally disabled.
•
Four sizes of convenient carry packs to assist the ambulatory patient in maintaining
independence of lifestyle.
•
Retained memory features that allow the pump to easily resume a therapy exactly from where
it left off when it is interrupted before completion or to repeat a therapy using the same
programmed prescription.
•
Compact, lockable safety shells that provide additional security when needed and that are
designed to be free standing, pole mounted, or placed in the convenient, soft carry case.
•
Backlit illumination for display screen. Backlight remains on continuously if AC Adaptor is
in use.
•
Integral Up as well as Down Occlusion alarms to notify user if an occlusion is present on
either side of the pumping chamber.
•
Integral High Upstream pressure alarm to notify user of excessive upstream pressure.
•
Integral Air-In-Line alarm to notify user of presence of air in the tubing.
•
Adjustable Down Occlusion settings of “High” and “Low” to customize the pump’s down
pressure requirements.
Regulatory Agency Approvals
INFUSION PUMP
WITH RESPECT TO ELECTRIC SHOCK, FIRE
AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH UL60601-1/CAN/CSA C22.2 NO.601.1
70TK
• Underwriters Laboratories has evaluated the
Moog Curlin Infusion
pump with AC
Adaptors 360-2026, 360-2022Kit , 47684 and 47685 to EN 60601-1 and CSA C22.2 No.
601-1 for General Standards of Safety for Medical Equipment and found the
Moog Curlin
Infusion
pump to be compliant.
• Underwriters Laboratories has evaluated the
Moog Curlin Infusion
pumps with accessory
equipments Battery Pack 360-2030 and the International AC Adaptors 360-2022Kit
and 47685 to EN 60601-2-24. Particular requirements for safety of infusion pumps and
controllers and they were found to be compliant.
•
Underwriters Laboratories has evaluated the
Moog Curlin Infusion
pump and the AC
Intr
oduction
Содержание CURLIN INFUSION PainSmart
Страница 24: ...21 Figure 2 8 Closing the Pump Door Pump Set Features...
Страница 39: ......
Страница 49: ......
Страница 113: ......
Страница 121: ......
Страница 125: ...118...
Страница 126: ...119 Technical Specifications...
Страница 127: ...120...
Страница 128: ...121 Technical Specifications...
Страница 129: ...122...
Страница 130: ...123 T...
Страница 131: ...124...
Страница 137: ......
Страница 139: ......
Страница 140: ......
Страница 141: ...Rev I 360 9043...