7 - 44 7 - 44
MELSEC-Q
7 FUNCTION
7.11.2 Interrupt program monitor list
(1) What is Interrupt Program Monitor List?
(a) This function displays execution count of the interrupt program (I0 to I255).
(b) This is used to confirm the execution status of the interrupt program.
(2) Using the Interrupt Program Monitor List
Choose "Online" "Monitor"
"Interrupt program monitor list". The "Interrupt
Program Monitor List" dialog box appears on screen.
The following shows an execution example of the interrupt program monitor list:
b)
a)
a) "Execute count"
The number of times the interrupt program was executed is displayed.
This function starts counting the number when High Performance
model QCPU is in RUN status (When the number reaches 65536
times, it is reset to 0).
b) "Common Comment"
This indicates device comments created on interrupt points (I0 to
I255).