App - 55 App - 55
MELSEC-Q
APPENDICES
Special Register List (Continue)
ACPU
Special
Conversion
Special
Register after
Conversion
Special
Register for
Modification
Name
Meaning
Details
Corresponding
CPU
D9248
SD1248
Stores conditions
for up to numbers 1
to 16
D9249
SD1249
Stores conditions
for up to numbers
17 to 32
D9250
SD1250
Stores conditions
for up to numbers
33 to 48
D9251
SD1251
Local station
operation
status
Stores conditions
for up to numbers
49 to 64
Stores the local station number which is in STOP or PAUSE
mode.
SD1248
SD1249
SD1250
SD1251
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
L16 L15 L14 L13 L12 L11
L32 L31 L30 L29 L28 L27
L48 L47 L46 L45 L44 L43
L64 L63 L62 L61 L60 L59
L26
L42
L58
L25
L41
L57
L24
L40
L56
L23
L39
L55
L22
L38
L54
L21
L37
L53
L20
L36
L52
L19
L35
L51
L18
L34
L50
L17
L33
L49
L10 L9
L8
L7
L6
L5
L4
L3
L2
L1
Bit
Device
number
The bit corresponding to the station number which is in
STOP or PAUSE mode, becomes "1".
Example: When local stations 7 and 15 are in STOP mode,
bits 6 and 14 of SD1248 become "1", and when
SD1248 is monitored, its value is "16448
(4040H)".
D9252
SD1252
Stores conditions
for up to numbers 1
to 16
D9253
SD1253
Stores conditions
for up to numbers
17 to 32
D9254
SD1254
Stores conditions
for up to numbers
33 to 48
D9255
SD1255
Local station
error
conditions
Stores conditions
for up to numbers
49 to 64
Stores the local station number other than the host, which is
in error.
SD1252
SD1253
SD1254
SD1255
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
L16 L15 L14 L13 L12 L11
L32 L31 L30 L29 L28 L27
L48 L47 L46 L45 L44 L43
L64 L63 L62 L61 L60 L59
L26
L42
L58
L25
L41
L57
L24
L40
L56
L23
L39
L55
L22
L38
L54
L21
L37
L53
L20
L36
L52
L19
L35
L51
L18
L34
L50
L17
L33
L49
L10 L9
L8
L7
L6
L5
L4
L3
L2
L1
Bit
Device
number
The bit corresponding to the station number which is in error,
becomes "1".
Example: When local station 12 is in error, bit 11 of SD1252
becomes "1", and when SD1252 is monitored, its
value is "2048 (800H) ".
QnA
(11) Fuse blown module
Number
Name
Meaning
Explanation
Set by
(When
set)
Corresponding
ACPU
D9
Corresponding
CPU
SD1300
D9100
SD1301
D9101
SD1302
D9102
SD1303
D9103
SD1304
D9104
SD1305
D9105
SD1306
D9106
SD1307
D9107
SD1308
New
SD1309
to
SD1330
New to New
SD1331
Fuse blown
module
Bit pattern in units
of 16 points,
indicating the
modules whose
fuses have blown
0: No blown fuse
1: Blown fuse
present
• The numbers of output modules whose fuses have blown are
input as a bit pattern (in units of 16 points).
(If the module numbers are set by parameter, the parameter-set
numbers are stored.)
• Also detects blown fuse condition at remote station output
modules
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
1
(YC0)
0
0
0
0
0
0
0
0
0
0
0
1
(Y80)
SD1300
0
0
1
(Y1F0)
0
0
0
0
0
0
0
0
0
0
1
(Y1A)
SD1301
0
0
0
0
1
(Y1F
B0)
0
0
0
0
0
0
0
0
SD1331
0
0
0
1
(Y1F
30)
0
Indicates a blown fuse
• Not cleared even if the blown fuse is replaced with a new one.
This flag is cleared by error resetting operation
(refer to 11.3.).
S (Error)
New
+Rem
SD1350
to
SD1381
External
power supply
disconnected
module
(For future
expansion)
Bit pattern in units
of 16 points,
indicating the
modules whose
external power
supply has been
disconnected
0: External power
supply
disconnected
1: External power
supply is not
disconnected
The module number (in units of 16 points) whose external power
supply has been disconnected is input as a bit pattern.
(If the module numbers are set by parameter, the parameter-set
numbers are used.)
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
SD1350
SD1351
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
0
1
0
0
SD1381
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
0
Indicates a blown fuse
S (Error)
New
QCPU
Remote