9 - 6 9 - 6
MELSEC-Q
9 PARAMETER LIST
Table 9.1 Parameter List (continued)
Item
Parameter No.
Description
I/O assignment
—
Designates the status of installation of each module of the system.
Type
Designates the type of the installed module.
Model name
Designates the model of the installed module. (Memorandum for
users who do not use the CPU module.)
Points
Designates the number of points of each slot.
I/O
Assign-
ment
Start
400
H
Designates the first input and output numbers of each slot.
Base model name
Designates the model of the used main base unit and extension
base unit. (Memorandum for users who do not use the CPU
module.)
Power model name
Designates the model of the power supply module installed to the
main and extension base units. (Memorandum for users who do
not use the CPU module)
Extension cable
Designates the model of the extension cable. (Memorandum for
users who do not use the CPU module)
Standard
setting
Points
401
H
Designates the number of slots of the main and extension base
units. The number of slots is designated for each base unit.
Switch setting
407
H
Designates various switches of the intelligent function module.
Error time output
module
403
H
Designates whether the output is cleared or retained upon a
stopping error of the control PLC.
H/W error time PLC
operation mode
404
H
Designates whether the control PLC continues operation or it is
stopped upon a hardware error of the intelligent function module.
I/O response time
405
H
Designates the response time of the input module, high speed
input module and I/O mixture module.
Detailed
setting
Control PLC
406
H
Designates the control PLC of the I/O module and intelligent
function module.
Acknowledge XY assignment
—
Contents of I/O allocation, MELSECNET/Ethernet setting and CC-
Link setting can be checked.
Multiple PLC setting
—
Defines settings for establishment of a multiple CPU system.
No. of PLC
E00
H
Designates the number of CPUs used in the multiple CPU system.
Operating mode
E01
H
Designates the operation of the multiple CPU system upon a
stopping error of the PLC No.2 to No.4 CPU modules.
The multiple CPU system is stopped if a stopping error occurs to
the PLC No.1 (Fixed)
Out of group input setting
Designates whether the input status of the input module and
intelligent function module controlled by other PLCs are acquired
or not.
Out of group output setting
E04
H
Designates whether the output status of the output module
controlled by other PLCs are acquired or not.
Refresh settings
E002
H
E003
H
Designates the devices and the number of points of data transfer
in automatic refresh between CPU modules of the multiple PLC
system.