6 - 12 6 - 12
MELSEC-Q
6 HIGH PERFORMANCE MODEL QCPU FILES
6.6 Writing Data to the Standard ROM or the Flash Card
6.6.1 Writing Data to the standard ROM or to the Flash card using GX Developer
The "write to PLC" function in the GX Developer Online menu does not allow the user
to write files into a standard ROM or on a Flash card. For writing files to a standard
ROM or to a Flash card by operating from GX Developer, GX Developer Online menu
provides two functions: "Write the program memory to ROM" and "Write to PLC (Flash
ROM)."
(1) Write the program memory to ROM
(a) The "Write the program memory to ROM" function allows a batch of files
stored in a program memory to be written to a standard ROM or a Flash
card. This function is used to debug the programs stored in the program
memory.
(b) When the "Write a memory to ROM" function is executed, all files stored in
the standard ROM or Flash card are erased before a batch of files stored in
a program memory are written. No files can be added to the standard ROM
or Flash card.
(c) The memory capacity of a standard ROM or Flash card is the same as that
of a program memory. A memory of a larger size than the memory capacity
of a program memory cannot be used.
(d) To execute the "Write the program memory to ROM" function, set the length
of GX developer's time-check to 60 seconds or longer. Shorter time-check
may cause a time-out on the GX Developer side. To execute the "Write the
program memory to ROM" function via the CC-Link network by operating
from a GX Developer at a local station, set the length of CC-Link's CPU
monitoring time (SW0A) to 60 seconds or longer. The default is 90
seconds. Use the default value when making the setting.
(2) Write to PLC (Flash ROM)
(a) The "Write to PLC (Flash ROM)" function is used to write a batch of files
specified by GX Developer to a standard ROM or Flash card.
(b) The "Write to PLC (Flash ROM)" function can fill all available space in a
standard ROM or Flash card. If a program that contains a small number of
steps is written to a Flash card, it will take long to fill the Flash card with
programs. When a RS-232 interface is mounted at Q2MEM-4MBF, a baud
rate of 115.2k bps takes about 14 minutes. To write data to a Flash card,
increase a baud rate or use a USB interface. If the "Write to PLC (Flash
ROM)" function is executed from a local station, communication time will be
longer.
(c) To execute the "Write to PLC (Flash ROM)" function, set the length of
GX Developer's time-check to 60 seconds or longer. Shorter time-check
may cause a time-out on the GX Developer side. To execute the "Write to
PLC (Flash ROM)" function via the CC-Link network by operating from GX
Developer at a local station, set the length of CC-Link's CPU monitoring
time (SW0A) to 60 seconds or longer. The default is 90 seconds. Use the
default value when making the setting.