12 - 3 12 - 3
MELSEC-Q
12 PROCEDURE FOR WRITING PROGRAMS TO HIGH PERFORMANCE
MODEL QCPU
Use the device
initial value?
1)
YES
NO
See Section 10.13.2.
Right-click on a device initial
value and select "Add" to spe-
cify a device initial value range.
In the boot file setting item in
the PLC parameter, designate
the file name of parameter and
program to be read from the
standard ROM.
In the program settings in the PLC
parameter, designate the name
of the program to be executed,
and its execution condition.
Connect the GX Developer to
the CPU module.
2)
In the PLC file setting in the
PLC parameter, designate the
name of file to be used for the
designated device initial values.
Set the CPU module's RUN/
STOP key to the STOP position,
then switch the power ON.
ERR. LED switches ON.
Right-click on the device
memory and select "Add" to
specify device initial value data.
Select the device memory to be
used in the device memory
registration setting of the device
initial value, and click on "Use
device memory".
In PLC memory format in the
GX Developer online mode,
select "Program memory/device
memory" and press "Execute"
(format the program memory).