Special Register List (Continued)
ACPU
Special
Conversion
Special
Register after
Conversion
Special
Register for
Modification
Name
Meaning
Details
Corresponding
CPU
D9085
SD1085
Register for
setting time
check value
Default value 10s
• Sets the time check time of the data link instructions
(ZNRD, ZNWR) for the MELSECNET/10.
• Setting range:
1 s to 65535 s (1 to 65535)
• Setting unit:
1 s
• Default value:
10 s (If 0 has been set, default
10 s is applied)
D9090
SD1090
Number of
special functions
modules over
Number of special
functions modules
over
• For details, refer to the manual of each microcompu-
ter program package.
D9091
SD1091
Detailed error
code
Self-diagnosis
detailed error code
• Stores the detail code of cause of an instruction error.
D9094
SD1094
SD251
Head I/O
number for
replacement
Head I/O number
for replacement
• Stores upper 2 digits of the head I/O address of I/O
modules to be loaded or unloaded during online mode
in BIN code.
Example) Input module
X2F0
→
H2F
D9100
SD1100
D9101
SD1101
D9102
SD1102
D9103
SD1103
D9104
SD1104
D9105
SD1105
D9106
SD1106
D9107
SD1107
Fuse blown
module
Bit pattern in units
of 16 points,
indicating the
modules whose
fuses have blown
• Output module numbers (in units of 16 points), of
which fuses have blown, are entered in bit pattern.
(Preset output unit numbers when parameter setting
has been performed.)
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
1
(Y80)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Y7
B0
SD1100
SD1101
SD1107
1
(YCO)
Indicates fuse blow.
1
Y7
30
• Fuse blow check is executed also to the output
module of remote I/O station.
(If normal status is restored, clear is not performed.
Therefore, it is required to perform clear by user
program.)
D9108
SD1108
D9109
SD1109
D9110
SD1110
D9111
SD1111
D9112
SD1112
D9113
SD1113
D9114
SD1114
Step transfer
monitoring timer
setting
Timer setting valve
and the f number at
time out
• Sets value for the step transfer monitoring timer and
the number of F which turns on when the monitoring
timer timed out.
Timer setting
(1 to 255 s in seconds)
F number setting
b15
b8 b7
b0
to
to
(By turning on any of MSM708 to SM1114, the
monitoring timer starts. If the transfer condition
following a step which corresponds to the timer is not
established within set time, set annunciator (F) is
tuned on.)
D9116
SD1116
D9117
SD1117
D9118
SD1118
D9119
SD1119
D9120
SD1120
D9121
SD1121
D9122
SD1122
D9123
SD1123
I/O module
verification error
Bit pattern, in units
of 16 points,
indicating the
modules with
verification errors.
• When I/O modules, of which data are different from
those entered at power-on, have been detected, the
I/O unit numbers (in units of 16 points) are entered in
bit pattern. (Preset I/O unit numbers when parameter
setting has been performed.)
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
XY
100
SD1116
SD1117
SD1123
1
XY
0
1
XY
100
0
0
0
Indicates I/O module verify error.
• I/O module verify check is executed also to remote I/O
station modules.
(If normal status is restored, clear is not performed.
Therefore, it is required to perform clear by user
program.)
Содержание QCPU (Q Mode)
Страница 111: ...5 19 5 19 MELSEC Q 5 ASSIGNMENT OF I O NUMBERS MEMO ...
Страница 450: ...App 59 App 59 MELSEC Q APPENDICES MEMO ...