7. PARAMETERS
7 - 35
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PB51
NHQ5
Notch shape
selection 5
Set forms of the machine resonance suppression filter 5.
When "Robust filter selection" is set to "Enabled (_ _ _ 1)" in [Pr. PE41], the machine resonance suppression filter
5 is not available.
_ _ _ x Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _ For manufacturer setting
0h
PB52
VRF21
Vibration
suppression
control 2 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
value out of the range is set, the vibration suppression control will be disabled. Refer
to section 7.1.5 of "MR-JE-_A Servo Amplifier Instruction Manual" for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB53
VRF22
Vibration
suppression
control 2 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
value out of the range is set, the vibration suppression control will be disabled. Refer
to section 7.1.5 of "MR-JE-_A Servo Amplifier Instruction Manual" for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB54
VRF23
Vibration
suppression
control 2 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
Refer to section 7.1.5 of "MR-JE-_A Servo Amplifier Instruction Manual" for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...