1. FUNCTIONS AND CONFIGURATION
1 - 8
(2) MR-JE-200A or more
The diagram shows MR-JE-200A.
Power factor
improving AC
reactor
(FR-HAL)
Line noise filter
(FR-BSF01)
CN3
Personal
computer
MR Configurator2
CN1
CN2
W
V
U
Magnetic
contactor
(MC)
L1
L2
L3
(Note 2)
Molded-case
circuit breaker
(MCCB)
R S T
Junction terminal block
Power
supply
(Note 1)
Servo motor
Note 1. A 1-phase 200 V AC to 240 V AC power supply may be used with the servo amplifier of MR-JE-200A. For 1-phase 200 V AC
to 240 V AC, connect the power supply to L1 and L2. Leave L3 open. For power supply specifications, refer to section 1.3 of
"MR-JE-_A Servo Amplifier Instruction Manual".
2 Depending on the power supply voltage and operation pattern, a bus voltage may drop, causing dynamic brake deceleration
during forced stop deceleration. When dynamic brake deceleration is not required, delay the time to turn off the magnetic
contactor.