5. HOW TO USE THE PROGRAM
5 - 51
5.4.9 Dog cradle type home position return
A position, which is specified by the first Z-phase signal after the front end of the proximity dog is detected, is
set as the home position.
(1) Device/parameter
Set input devices and parameters as follows:
Item
Device/parameter to be used
Setting
Automatic operation mode of
the program method
MD0 (Operation mode selection 1)
Switch on MD0.
Dog cradle type home
position return
[Pr. PT04]
_ _ _ 7: Select the dog cradle type.
Home position return
direction
[Pr. PT04]
Refer to section 5.4.1 (2) to select the home
position return direction.
Dog input polarity
[Pr. PT29]
Refer to section 5.4.1 (2) to select the dog input
polarity.
Home position return speed
[Pr. PT05]
Set the rotation speed specified until a dog is
detected.
Creep speed
[Pr. PT06]
Set the rotation speed specified after a dog is
detected.
Home position shift distance
[Pr. PT07]
Set this to shift the home position, which is
specified by the Z-phase signal.
Acceleration time constant of
home position return
[Pr. PC30]
The acceleration time constant set for [Pr. PC30]
is used.
Deceleration time constant of
home position return
[Pr. PC31]
The deceleration time constant set for [Pr. PC31]
is used.
Home position return position
data
[Pr. PT08]
Set the current position when the home position
return completed.
Program
DI0 (Program No. selection 1) to
DI3 (Program No. selection 4)
Select a program containing a "ZRT" command,
which performs the home position return.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...