4. HOW TO USE THE POINT TABLE
4 - 38
Operation sequence
1) Starting with point table No. 1
2) Varying the speed and executing point table No. 2
3) Executing again point table No. 1 used at start-up when "8" is set to the auxiliary function of
point table No. 2
4) Repeating the above execution in the sequence of 1) to 2) to 3) to 2) to 3)
Servo motor speed
Forward
rotation
Reverse
rotation
Position address
Selected point table No.
ST1
(Forward rotation start)
ON
OFF
PT0 (Point table No. output 1)
to PT4 (Point table No. output 5)
(Note 1)
M code output (Note 1, 2)
Speed
Point table No. 1
Speed
5.00
0
5.00
11.00
1
5.00
1)
2)
2)
3)
6.00
16.00
Speed
Speed
Point table No. 2
0 r/min
(3000)
(2000)
(3000)
(2000)
Note 1. PT0 to PT4 and M code are not outputted in automatic continuous operation.
2. M code will be available in the future.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...