![Mitsubishi MR-JE-100A Скачать руководство пользователя страница 332](http://html1.mh-extra.com/html/mitsubishi/mr-je-100a/mr-je-100a_instruction-manual_1808430332.webp)
7. PARAMETERS
7 - 57
7.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PE41
EOP3
Function
selection E-3
_ _ _ x Robust filter selection
0: Disabled
1: Enabled
When "Enabled" is set, the machine resonance suppression filter 5 that is set in [Pr.
PB51] is not available.
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PE44
LMCP
Lost motion
compensation
positive-side
compensation
value
selection
Set the lost motion compensation for when reverse rotation (CW) switches to
forward rotation (CCW) in increments of 0.01% assuming the rated torque as 100%.
This parameter is available with servo amplifiers with software version C5 or later.
Setting range: 0 to 30000
0
[0.01%]
PE45
LMCN
Lost motion
compensation
negative-side
compensation
value
selection
Set the lost motion compensation for when forward rotation (CCW) switches to
reverse rotation (CW) in increments of 0.01% assuming the rated torque as 100%.
This parameter is available with servo amplifiers with software version C5 or later.
Setting range: 0 to 30000
0
[0.01%]
PE46
LMFLT
Lost motion
filter setting
Set the time constant of the lost motion compensation filter in increments of 0.1 ms.
If the time constant is "0", the torque is compensated with the value set in [Pr. PE44]
and [Pr. PE45]. If the time constant is other than "0", the torque is compensated with
the high-pass filter output value of the set time constant, and the lost motion
compensation will continue.
This parameter is available with servo amplifiers with software version C5 or later.
Setting range: 0 to 30000
0
[0.1 ms]
PE47
TOF
Torque offset
Set this when canceling unbalanced torque of vertical axis. Set this assuming the
rated torque of the servo motor as 100%. The torque offset does not need to be set
for a machine not generating unbalanced torque.
This parameter is available with servo amplifiers with software version C5 or later.
Setting range: -10000 to 10000
0
[0.01%]
PE48
*LMOP
Lost motion
compensation
function
selection
_ _ _ x Lost motion compensation selection
0: Disabled
1: Enabled
This parameter is available with servo amplifiers with software version C5 or later.
0h
_ _ x _ Unit setting of lost motion compensation non-sensitive band
0: 1 pulse unit
1: 1 kpulse unit
This parameter is available with servo amplifiers with software version C5 or later.
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PE49
LMCD
Lost motion
compensation
timing
Set the lost motion compensation timing in increments of 0.1 ms.
You can delay the timing to perform the lost motion compensation for the set time.
This parameter is available with servo amplifiers with software version C5 or later.
Setting range: 0 to 30000
0
[0.1 ms]
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...