3. DISPLAY AND OPERATION SECTIONS
3 - 6
Status display
Symbol
Unit
Description
Control
mode
(Note 1)
CP CL
Unit power consumption 1
(1 W unit)
PC1 W
Unit power consumption is displayed by increment of 1 W.
Positive value indicates power running, and negative value
indicates regeneration. The values in excess of ±99999 can be
counted. However, the counter shows only the lower five digits of
the actual value since the servo amplifier display is five digits.
Unit power consumption 2
(1 kW unit)
PC2 kW
Unit power consumption is displayed by increment of 1 kW.
Positive value indicates power running, and negative value
indicates regeneration.
Unit total power
consumption 1
(1 Wh unit)
TPC1 Wh
Unit total power consumption is displayed by increment of 1 Wh.
Positive value is cumulated during power running and negative
value during regeneration. The values in excess of ±99999 can
be counted. However, the counter shows only the lower five
digits of the actual value since the servo amplifier display is five
digits.
Unit total power
consumption 2
(100 kWh unit)
TPC2 100
kWh
Unit total power consumption is displayed by increment of 100
kWh. Positive value is cumulated during power running and
negative value during regeneration.
Current position
PoS
10
STM
μ
m
10
(STM-4)
inch
10
-3
degree
pulse
(Note 2)
When "_ _ 0 _" (positioning display) is set in [Pr. PT26], the
current position is displayed as machine home position is 0.
When "_ _ 1 _" (roll feed display) is set in [Pr. PT26], the actual
current position is displayed as start position is 0.
The values in excess of ±99999 can be counted. However, the
counter shows only the lower five digits of the actual value since
the servo amplifier display is five digits.
Command position
CPoS
10
STM
μ
m
10
(STM-4)
inch
10
-3
degree
pulse
(Note 2)
When "_ _ 0 _" (positioning display) is set in [Pr. PT26], the
command current position is displayed as machine home position
is 0.
When "_ _ 1 _" (roll feed display) is set in [Pr. PT26], turning on
the start signal starts counting from 0 and a command current
position to the target position is displayed in the automatic mode.
The command positions of the selected point table are displayed
at a stop. At the manual mode, the command positions of the
selected point table are displayed.
The values in excess of ±99999 can be counted. However, the
counter shows only the lower five digits of the actual value since
the servo amplifier display is five digits.
Command remaining
distance
rn
10
STM
μ
m
10
(STM-4)
inch
10
-3
degree
pulse
(Note 2)
The remaining distance to the command position of the currently
selected point table/program is displayed.
The values in excess of ±99999 can be counted. However, the
counter shows only the lower five digits of the actual value since
the servo amplifier display is five digits.
Point table No./Program
No.
Pno
The point table No./program No. currently being executed is
displayed. The selected number is displayed during a temporary
stop or manual operation.
Step No.
Sno
The step No. of the program currently being executed is
displayed. At a stop, 0 is displayed.
Analog override voltage
oru
V
The analog override voltage is displayed.
Override level
or
%
The setting value of the override is displayed.
When the override is disabled, 100% is displayed.
Cam axis one cycle
current value
CCyC
10
STM
μ
m
10
(STM-4)
inch
10
-3
degree
pulse
(Note 3)
The current position in one cycle of CAM axis is displayed with
the range of "0 to (cam axis one cycle length - 1)", the cam axis
one cycle current value which is calculated from the travel
distance inputted to the cam axis.
The values in excess of ±99999 can be counted. However, the
counter shows only the lower five digits of the actual value since
the servo amplifier display is five digits.
When the simple cam function is disabled, 0 is always displayed.
Refer to section 6.1.8 for detecting point.
Cam standard position
CbAS
10
STM
μ
m
10
(STM-4)
inch
10
-3
degree
pulse
(Note 2)
A feed current value which is the standard position of the cam
operation is displayed.
The values in excess of ±99999 can be counted. However, the
counter shows only the lower five digits of the actual value since
the servo amplifier display is five digits.
When the simple cam function is disabled, 0 is always displayed.
Refer to section 6.1.8 for detecting point.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...