7. PARAMETERS
7 - 2
7.1.1 Basic setting parameters ([Pr. PA_ _ ])
POINT
To enable the following parameters in the positioning mode, turn off the power
for 1 s or more after setting and turn it on again. However, the time will be longer
depending on a setting value of [Pr. PF25 Instantaneous power failure tough
drive - Detection time] when "instantaneous power failure tough drive selection"
is enabled in [Pr. PA20].
[Pr. PA06 Electronic gear numerator (command pulse multiplication
numerator)/Number of gear teeth on machine side]
[Pr. PA07 Electronic gear denominator (command pulse multiplication
denominator)/Number of gear teeth on servo motor side]
The following parameter cannot be used in the positioning mode.
[Pr. PA05 Number of command input pulses per revolution]
No. Symbol
Name
Initial
value
Unit
Control
mode
CP CL
PA01 *STY Operation
mode
1000h
PA02 *REG Regenerative
option
0000h
PA03
For manufacturer setting
0000h
PA04
*AOP1 Function selection A-1
2000h
PA05
*FBP
Number of command input pulses per revolution
10000
PA06
*CMX
Electronic gear numerator (command pulse multiplication
numerator)
1
PA07
*CDV
Electronic gear denominator (command pulse multiplication
denominator)
1
PA08
ATU
Auto tuning mode
0001h
PA09
RSP
Auto tuning response
16
PA10 INP In-position
range
100
[
μ
m]/
10
-4
[inch]/
10
-3
[degree]/
[pulse]
PA11
TLP
Forward rotation torque limit
100.0
[%]
PA12
TLN
Reverse rotation torque limit
100.0
[%]
PA13
*PLSS
Command pulse input form
0100h
PA14
*POL
Rotation direction selection
0
PA15
*ENR
Encoder output pulses
4000
[pulse/rev]
PA16
*ENR2 Encoder output pulses 2
1
PA17 For manufacturer setting
0000h
PA18
0000h
PA19
*BLK
Parameter writing inhibit
00AAh
PA20
*TDS
Tough drive setting
0000h
PA21
*AOP3 Function selection A-3
0001h
PA22
For manufacturer setting
0000h
PA23
DRAT
Drive recorder arbitrary alarm trigger setting
0000h
PA24
AOP4
Function selection A-4
0000h
PA25 OTHOV One-touch tuning - Overshoot permissible level
0
[%]
PA26
*AOP5 Function selection A-5
0000h
PA27 For manufacturer setting
0000h
PA28
0000h
PA29
0000h
PA30
0000h
PA31
0000h
PA32
0000h
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...