4. HOW TO USE THE POINT TABLE
4 - 14
(b) Parameter setting
Set the following parameters to perform automatic operation.
1) Command method selection ([Pr. PT01])
Select the absolute value command method as shown below.
[Pr. PT01]
0
Absolute value command method
2) Rotation direction selection ([Pr. PA14])
Select the servo motor rotation direction when ST1 (Forward rotation start) is switched on.
[Pr. PA14] setting
Servo motor rotation direction when ST1
(Forward rotation start) is switched on
0
CCW rotation with + position data
CW rotation with - position data
1
CW rotation with + position data
CCW rotation with - position data
CW
CCW
3)
Position data unit ([Pr. PT01])
Set the unit of the position data.
[Pr. PT01] setting
Position data unit
_ 0 _ _
mm
_ 1 _ _
inch
_ 2 _ _
degree
_ 3 _ _
pulse
4) Feed length multiplication ([Pr. PT03])
Set the feed length multiplication factor (STM) of the position data.
[Pr. PT03] setting
Position data input range
[mm]
[inch]
[degree] (Note 1)
[pulse] (Note 1)
_ _ _ 0
- 999.999 to + 999.999
- 99.9999 to + 99.9999
_ _ _ 1
- 9999.99 to + 9999.99
- 999.999 to + 999.999
- 360.000 to + 360.000
(Note 2)
- 999999 to + 999999
_ _ _ 2
- 99999.9 to + 99999.9
- 9999.99 to + 9999.99
_ _ _ 3
- 999999 to + 999999
- 99999.9 to + 99999.9
Note 1. The feed length multiplication setting ([Pr. PT03]) is not applied to the unit multiplication factor.
Adjust the unit multiplication factor in the electronic gear setting ([Pr. PA06] and [Pr. PA07]).
2. The "-" sign has different meanings under the absolute value command method and the incremental value command method.
Refer to section 4.2.1 for details.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...