![Mitsubishi MR-JE-100A Скачать руководство пользователя страница 235](http://html1.mh-extra.com/html/mitsubishi/mr-je-100a/mr-je-100a_instruction-manual_1808430235.webp)
6. APPLICATION OF FUNCTIONS
6 - 22
3) Cam axis one cycle length setting (2D84h)
Address Name
Data
type
Read/write
No. of points/
No. of Registers
Continuous
read/
continuous
write
2D84h One cycle length of CAM axis
4 bytes
Write
2
Impossible
The cam axis one cycle length can be written in the RAM space in the servo amplifier using the
function code "10h" (Preset Multiple Registers).
The values set with this register are deleted at power-off.
4) Cam stroke length setting (2D85h)
Address Name
Data
type
Read/write
No. of points/
No. of Registers
Continuous
read/
continuous
write
2D85h Stroke movement of CAM
4 bytes
Write
2
Impossible
A cam stroke length can be written in the RAM space in the servo amplifier using the function
code "10h" (Preset Multiple Registers).
The values set with this register are deleted at power-off.
5) Request store CAM (2D88h)
Address Name
Data
type
Read/write
No. of points/
No. of Registers
Continuous
read/
continuous
write
2D88h Request store CAM
1 byte
Write
1
Impossible
Cam data can be written in the RAM space in the servo amplifier using the function code "10h"
(Preset Multiple Registers). Always set "0" in this register.
The values set with this register are deleted at power-off.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...