![Mitsubishi MR-JE-100A Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/mitsubishi/mr-je-100a/mr-je-100a_instruction-manual_1808430170.webp)
5. HOW TO USE THE PROGRAM
5 - 25
(h) Number of program executions command (TIMES)
A program can be executed repeatedly by setting the number of program executions in the "TIMES
(setting value) command" placed at the start of the program. To execute the program one time, the
"TIMES" command is not required. Setting "0" repeats the operation endlessly. For how to stop the
program in this status, refer to section 5.2.4 (4).
Command Description
TIMES (2)
Number of program executions command
2 [time]
a)
SPN (1000)
Servo motor speed
1000 [r/min]
STC (20)
Acceleration/deceleration time constant
20 [ms]
MOVI (1000)
Incremental value travel command
1000 [×10
STM
μ
m] b)
TIM (100)
Dwell
100 [ms]
STOP Program
stop
b) Incremental value
travel command
(100 × 10
STM
μ
m)
Servo motor
speed
a)
1000
1200
Reverse rotation
0 r/min
Forward rotation