4. HOW TO USE THE POINT TABLE
4 - 43
4.3 Manual operation mode
For the machine adjustment, home position adjustment, and others, positioning to any point is possible using
the JOG operation or the manual pulse generator.
4.3.1 JOG operation
(1) Setting
According to the purpose of use, set input devices and parameters as shown below. In this case, DI0
(Point table No. selection 1) to DI4 (Point table No. selection 5) are disabled.
Item
Device/parameter to be used
Setting
Manual operation mode
selection
MD0 (Operation mode selection 1)
Switch off MD0.
Servo motor rotation direction [Pr. PA14]
Refer to (2) in this section.
JOG speed [Pr.
PT13]
Set the servo motor speed.
Acceleration time
constant/Deceleration time
constant
Point table No. 1
The acceleration/deceleration time constant
of point table No. 1 is used.
(2) Servo motor rotation direction
[Pr. PA14] setting
Servo motor rotation direction
ST1 (Forward rotation start) on
ST2 (Reverse rotation start) on
0 CCW
rotation
CW
rotation
1
CW rotation
CCW rotation
[Pr. PA14]: 0
[Pr. PA14]: 1
CW
ST2: on
CW
ST1: on
ST2: on
CCW
ST1: on
CCW
(3) Operation
Switching on ST1 (Forward rotation start) performs the operation at the JOG speed set by a parameter
and the acceleration/deceleration constant of point table No. 1. For the rotation direction, refer to (2) of
this section. Switching on ST2 (Reverse rotation start) starts the rotation in the reverse direction of ST1
(Forward rotation start).
Simultaneously switching on or off ST1 (Forward rotation start) and ST2 (Reverse rotation start) stops
the operation.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...