![Mitsubishi MR-JE-100A Скачать руководство пользователя страница 303](http://html1.mh-extra.com/html/mitsubishi/mr-je-100a/mr-je-100a_instruction-manual_1808430303.webp)
7. PARAMETERS
7 - 28
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PB12
OVA
Overshoot
amount
compensation
Set a viscous friction torque in percentage to the rated torque at servo motor rated
speed.
When the response level is low, or when the torque is limited, the efficiency of the
parameter can be lower.
Setting range: 0 to 100
0
[%]
PB13
NH1
Machine
resonance
suppression
filter 1
Set the notch frequency of the machine resonance suppression filter 1.
When "Filter tuning mode selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB01], this parameter will be adjusted automatically by adaptive tuning.
When "Filter tuning mode selection" is set to "Manual setting (_ _ _ 2)" in [Pr. PB01],
the setting value will be enabled.
Setting range: 10 to 4500
4500
[Hz]
PB14
NHQ1
Notch shape
selection 1
Set forms of the machine resonance suppression filter 1.
When "Filter tuning mode selection" is set to "Automatic setting (_ _ _ 1)" in [Pr. PB01], this parameter will be
adjusted automatically by adaptive tuning.
When "Filter tuning mode selection" is set to "Manual setting (_ _ _ 2)" in [Pr. PB01], the setting value will be
enabled.
_ _ _ x For manufacturer setting
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _ For manufacturer setting
0h
PB15
NH2
Machine
resonance
suppression
filter 2
Set the notch frequency of the machine resonance suppression filter 2.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 2 selection" in [Pr. PB16].
Setting range: 10 to 4500
4500
[Hz]
PB16
NHQ2
Notch shape
selection 2
Set forms of the machine resonance suppression filter 2.
_ _ _ x Machine resonance suppression filter 2 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _ For manufacturer setting
0h
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...