4. HOW TO USE THE POINT TABLE
4 - 22
c) Position data in degrees
The following shows an operation example with the set values listed in the table below.
In this example, point table No. 1, No. 2, and No. 4 are set to the absolute value command
method, and point table No. 3 the incremental value command method.
Point table
No.
Position data
[degree]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
M code
(Note 2)
1 120.000
1000 100
150
100
1 05
2
-320 .000 500
150
100 200
1
10
3 -230.000
3000
200 300
150 3
15
4
70.000
1500 300
100 Disabled
0 (Note 1)
20
Note 1. Always set "0" or "2" to the auxiliary function of the last point table of the consecutive point tables.
0: When using the point table with the absolute value command method
2: When using the point table with the incremental value command method
2. M code will be available in the future.
120
(-240)
40
(-320)
230
170
(-190)
70
(-290)
170
(-190)
120
(-240)
40
(-320)
0
0
0
0
Servo motor speed
Selected point table No.
ST1
(Forward rotation start)
ON
OFF
PT0 (Point table No. output 1)
to PT4 (Point table No. output 5)
(Note 1)
M code output (Note 2)
Point table No. 2
Point table No. 4
1
1
05
Point table No. 3
Point table No. 1
Forward
rotation
Reverse
rotation
0 r/min
Note 1. For MR-JE-_A servo amplifiers, up to four points of DO are available; therefore, PT0 to PT4 cannot be
outputted simultaneously.
2. M code will be available in the future.
Содержание MR-JE-100A
Страница 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Страница 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Страница 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Страница 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Страница 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Страница 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Страница 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...