4. HOW TO USE THE POINT TABLE
4 - 1
4. HOW TO USE THE POINT TABLE
The following items are the same as MR-JE-_A servo amplifiers. For details, refer to each section indicated
in the detailed explanation field. "MR-JE-_A" means "MR-JE-_A Servo Amplifier Instruction Manual".
Item Detailed
explanation
Switching power on for the first time
MR-JE-_A section 4.1
POINT
For the mark detection function (Current position latch), refer to section 6.2.2.
For the mark detection function (Interrupt positioning), refer to section 6.2.3.
There are the following restrictions on the number of gear teeth on machine side
([Pr. PA06 Number of gear teeth on machine side]) and the servo motor speed
(N).
When CMX
≤
2000, N < 3076.7 r/min
When CMX > 2000, N < (3276.7 - CMX)/10 r/min
When the servo motor is operated at a servo motor speed higher than the limit
value, [AL. E3 Absolute position counter warning] will occur.