2. Local remote controller
3 - 11
CONTROLLER
Controller
2-8. LOSSNAY remote controller for LGH-RX5-E [PZ-60DR-E]
Stand-alone LOSSNAY operation is possible by
commands from a centralized controller or LOSSNAY
remote controller. (AG-150A/GB-50A are centralized
controllers that support LOSSNAY operation.)
The LOSSNAY remote controller is capable of
changing the air flow and vent modes.
All the wiring is cross-wiring that uses non-polar
two wire system signal cables.
: When setting up a LOSSNAY stand-alone system or when set-
ting up a LOSSNAY and centralized controller system, connect a
power supply unit for the signal cables.
:
:
It is possible to use a LOSSNAY remote controller for LOSSNAY
It is not possible to connect to LGH-RX4-E.
unit that is interlocked with other indoor units.
External dimension
System example
Functions (in case of LGH-RX5-E)
Screw Position
46
130
19
120
83.5
LOSSNAY independent
Interlocked with Air conditioners
Interlocked with Indoor unit
Indoor unit
M-NET transmission line
LOSSNAY
RX
5
LOSSNAY remote
controller
PZ-60DR-E
LOSSNAY remote
controller
PZ-60DR-E
can be connected
LOSSNAY RX
5
(Max 15 unit)
PZ-52SF-E can be used instead of PZ-60DR-E,
However, function is limited and connecting
position is different.
PZ-41SLB-E can be connected however function
is limited.
New Function
Extra low fan speed (Except LGH-150RX
5
and 200RX
5
)
Weekly timer
Simple timer
Night Purge mode
Multi languages display
24-hours ventilation (Except LGH-150RX
5
and 200RX
5
)
Operation function limit
Clock display
Contact number setting for error situation
LOSSNAY core cleaning sign
Air volume display by external signal
Bypass display by external signal
Possible setting from the controller in addition to unit Dip-SW setting
Extra High / High switch setting
Multi Ventilation mode
Power supply / exhaust when operation starts
Pulse input
Inter locking mode
Automatic recovery following power supply interruption
Delay operation at heating or cooling start-up
Operation output monitor
Exhaust fan stop at outdoor air lower than -15°C
Exhaust fan stop during defrosting,exhaust fan Low speed operation at outdoor air lower than -15°C
Bypass automatic ventilation priority setting
Filter cleaning sign
Maintenance display
Total operated hours
Total LOSSNAY mode operated hours
Error history
Carry on function
In the use of MELANS M-NET
2 controllers display
"Central" indication(use prohibition)
Function(Communicating mode)
Содержание PURY-WP-YJM-A
Страница 1: ...DATA BOOK PURY WP YJM A CMB WP V G PEFY WP VMS1 E PEFY WP VMA E PFFY WP VLRMM E MODEL 3rd edition ...
Страница 3: ...Databook ...
Страница 5: ...1 2 INDOOR UNITS ...
Страница 39: ...1 36 INDOOR UNITS ...
Страница 51: ...1 48 INDOOR UNITS ...
Страница 61: ...1 58 INDOOR UNITS ...
Страница 68: ...2 1 HYBRID CITY MULTI OUTDOOR UNITS 2 OUTDOOR UNITS HYBRID CITY MULTI 2 3 ...
Страница 69: ...2 2 OUTDOOR UNITS ...
Страница 85: ...2 18 OUTDOOR UNITS ...
Страница 172: ...4 1 HYBRID CITY MULTI SYSTEM DESIGN 4 SYSTEM DESIGN SYSTEM DESIGN 4 3 ...
Страница 173: ...4 2 SYSTEM DESIGN ...