1. SPECIFICATIONS
OUTDOOR UNITS
2 - 4
OUTDOOR
I.HYBRID CITY MULTI
1. SPECIFICATIONS
Model
PURY-WP200YJM-A
PURY-WP250YJM-A
Power source
3-phase 4-wire 380-400-415 V 50/60 Hz
3-phase 4-wire 380-400-415 V 50/60 Hz
Cooling capacity
Cooling 100%
Cooling 100%
(Nominal)
*1 kW
22.4
28.0
*1 kcal/h
19,300
24,100
*1 BTU/h
76,400
95,500
Power input
kW
4.79
6.99
Current input
A
8.0-7.6-7.4
11.8-11.2-10.8
COP
kW/kW
4.67
4.00
Temp. range of
Indoor
W.B.
15.0~24.0 °C (59~75 °F)
15.0~24.0 °C (59~75 °F)
cooling
Outdoor
D.B.
-5.0~46.0 °C (23~115 °F)
-5.0~46.0 °C (23~115 °F)
Heating capacity
Heating 100%
Heating 100%
(Nominal)
*2 kW
25.0
31.5
*2 kcal/h
21,500
27,100
*2 BTU/h
85,300
107,500
Power input
kW
5.28
6.98
Current input
A
8.9-8.4-8.1
11.7-11.1-10.7
COP
kW/kW
4.73
4.51
Temp. range of
Indoor
D.B.
15.0~27.0 °C (59~81 °F)
15.0~27.0 °C (59~81 °F)
heating
Outdoor
W.B.
-20.0~15.5 °C (-4~60 °F)
-20.0~15.5 °C (-4~60 °F)
Indoor unit
Total capacity
50~150%
50~150%
connectable
Model / Quantity
WP15~WP50/1~20
WP15~WP50/1~24
Sound pressure level (measured in anechoic room) dB <A>
60
60
Power pressure level (measured in anechoic room) dB <A>
80
80
Refrigerant
High pressure
mm (in.)
15.88 (5/8) Brazed
19.05 (3/4) Brazed
piping diameter
Low pressure
mm (in.)
19.05 (3/4) Brazed
22.2 (7/8) Brazed
FAN
Type x Quantity
Propeller fan x 1
Propeller fan x 1
Air flow rate
m
3
/min
225
225
L/s
3,750
3,750
cfm
7,945
7,945
Control, Driving mechanism
Inverter-control, Direct-driven by motor
Inverter-control, Direct-driven by motor
Motor output
kW
0.92 x 1
0.92 x 1
*3 External static press.
0 Pa (0 mmH
2
O)
0 Pa (0 mmH
2
O)
Compressor
Type x Quantity
Inverter scroll hermetic compressor
Inverter scroll hermetic compressor
Manufacture
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Starting method
Inverter
Inverter
Motor output
kW
5.4
6.8
Case heater
kW
0.045 (240 V)
0.045 (240 V)
Lubricant
MEL32
MEL32
External finish
Pre-coated galvanized steel sheets (+powder coating for -BS
type)
Pre-coated galvanized steel sheets (+powder coating for -BS
type)
<MUNSELL 5Y 8/1 or similar>
<MUNSELL 5Y 8/1 or similar>
External dimension HxWxD
mm
1,710 (1,650 without legs) x 1,220 x 760
1,710 (1,650 without legs) x 1,220 x 760
in.
67-3/8 (65 without legs) x 48-1/16 x 29-15/16
67-3/8 (65 without legs) x 48-1/16 x 29-15/16
Protection devices
High pressure protection
High pressure sensor, High pressure switch at 4.15 MPa (601
psi)
High pressure sensor, High pressure switch at 4.15 MPa (601
psi)
Inverter circuit (COMP./FAN)
Over-current protection
Over-current protection
Fan motor
Thermal switch
Thermal switch
Refrigerant
Type x original charge
R410A x 11.8 kg (27 lbs)
R410A x 11.8 kg (27 lbs)
Control
LEV and HIC circuit
LEV and HIC circuit
Net weight
kg (lbs)
270 (596)
270 (596)
Heat exchanger
Salt-resistant cross fin & copper tube
Salt-resistant cross fin & copper tube
HIC circuit (HIC: Heat Inter-Changer)
-
-
Defrosting method
Auto-defrost mode (Reversed refrigerant cycle)
Auto-defrost mode (Reversed refrigerant cycle)
Drawing
External
-
-
Wiring
-
-
Standard attachment
Document
Installation Manual
Installation Manual
Accessory
Refrigerant conn. pipe
Refrigerant conn. pipe
Optional parts
Remarks
Details on foundation work, duct work, insulation work, electri-
cal wiring, power source switch, and other items shall be re-
ferred to the Installation Manual.
Due to continuing improvement, above specifications may be
subject to change without notice.
Details on foundation work, duct work, insulation work, electri-
cal wiring, power source switch, and other items shall be re-
ferred to the Installation Manual.
Due to continuing improvement, above specifications may be
subject to change without notice.
Notes :
Unit converter
1.Nominal HVRF cooling conditions
Indoor: 27 °CD.B./19 °CW.B. (81 °FD.B./66 °FW.B.), Outside: 35 °CD.B. (95 °FD.B.)
Water pipe length: 5 m (16-3/8 ft.), Refrigerant pipe length: 2.5 m (8-3/16 ft.), Level deference: 0 m (0 ft.)
2.Nominal HVRF heating conditions
Indoor: 20 °CD.B. (68 °FD.B.), Outside: 7 °CD.B./6 °CW.B. (45 °FD.B./43 °FW.B.)
Water pipe length: 5 m (16-3/8 ft.), Refrigerant pipe length: 2.5 m (8-3/16 ft.), Level deference: 0 m (0 ft.)
3.External static pressure option is available (30 Pa, 60 Pa/3.1 mmH
2
O, 6.1 mmH
2
O).
kcal
=kW x 860
BTU/h =kW x 3,412
cfm
=m
3
/min x 35.31
lbs
=kg / 0.4536
*Above specification data is
subject to rounding variation.
Содержание PURY-WP-YJM-A
Страница 1: ...DATA BOOK PURY WP YJM A CMB WP V G PEFY WP VMS1 E PEFY WP VMA E PFFY WP VLRMM E MODEL 3rd edition ...
Страница 3: ...Databook ...
Страница 5: ...1 2 INDOOR UNITS ...
Страница 39: ...1 36 INDOOR UNITS ...
Страница 51: ...1 48 INDOOR UNITS ...
Страница 61: ...1 58 INDOOR UNITS ...
Страница 68: ...2 1 HYBRID CITY MULTI OUTDOOR UNITS 2 OUTDOOR UNITS HYBRID CITY MULTI 2 3 ...
Страница 69: ...2 2 OUTDOOR UNITS ...
Страница 85: ...2 18 OUTDOOR UNITS ...
Страница 172: ...4 1 HYBRID CITY MULTI SYSTEM DESIGN 4 SYSTEM DESIGN SYSTEM DESIGN 4 3 ...
Страница 173: ...4 2 SYSTEM DESIGN ...