2. Local remote controller
3 - 5
CONTROLLER
Controller
2-2. MA remote controller [PAR-21MAA]
Functions
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK
DAY
MONITOR/SET
CLOCK
ON/OFF
ERROR CODE
AFTER
TIMER
TIME SUN MON TUE WED THU FRI SAT
ON
OFF
Hr
AFTER
FILTER
FUNCTION
ONLY1Hr.
WEEKLY
SIMPLE
AUTO OFF
MA
remote
controller
Non-polarized
2-wire
Non-
polarized
2-wire
MA
remote
controller
High-quality white color body and light-green display.
Dot LCD is applied.
Choose from Japanese, Chinese, English, German,
Spanish, Russian, Italian, French displays.
Connectable to all HYBRID CITY MULTI indoor units, and
automatically adjust its function with the connected indoor unit.
Auto-stop timer is available.
Weekly scheduler is available.
ON/OFF/Temperature setting 8 times per day, 1 week
scheduling.
Grouping via cross-over wire directly.
Usable as the local remote controller for system con-
troller (MELANS)
Combining ME remote controller and/or LOSSNAY
remote controller in a group is not possible.
System example
ON/OFF
ON and OFF operation for a single group
Operation mode
switching
Switches between Cool / Dry / Auto / Fan / Heat.
Operation modes vary depending on the air conditioner unit.
Temperature
setting
Fan speed
setting
Models with 4 air flow speed settings: Hi/Mid-1/Mid-2/Low
Models with 3 air flow speed settings: Hi/Mid/Low
Models with 2 air flow speed settings: Hi/Low
Fan speed setting (including Auto) varies depending on the
model.
Air flow
direction
setting
Permit / Prohibit
local operation
Weekly
scheduler
Individually prohibit operation of each local remote control
function (ON/OFF, Change operation mode, Set
temperature, Reset filter).
1: When the local remote controller inactivation command
is received from the main system controller,
" " is displayed.
Indoor unit intake
temperature
Prohibition/permission
of specified mode
(Cooling prohibited
/heating prohibited
/cooling-heating prohibited)
Measures the intake temperature of the indoor unit when
the indoor unit is operating.
Error
When an error is currently occurring on an air conditioner
unit, the afflicted unit and the error code are displayed.
Test run
This operates air conditioner units in test run mode.
Ventilation
equipment
Up to 16 indoor units can be connected to an interlocked
system that has one LOSSNAY. LOSSNAY items that can
be set are "Hi" "Low" "Stop". Ventilation mode switching is
not available.
Item
Description
Operations
Display
Air flow direction angles (4-angle, or 5-angle Swing) Auto
Louver ON/OFF
Air flow direction settings vary depending on the model.
ON/OFF/Temperature setting can be done up to 8 times one
day in the week.
The time can be set by the minute.
By the setting from System Controller, the operation for the
following modes is prohibited.
At cooling prohibited
: Cool, Dry, Auto,
At heating prohibited
: Heat, Auto,
At cooling-heating prohibited
: Cool, Heat, Dry, Auto
1
:Each unit
:Collective
:Each block
:Each group
:Each floor
:Not available
Sets the temperature for a single group
Range of temperature setting
Cool/Dry :
:
Auto
:
( ) For PEFY/PFFY by setting DipSW 7-1 to ON and limits to NI6H fan speed only.
Function to limit
the setting range
of room
temperature
(Set temperature
range limit)
Set temperature range limit to cooling, heating, or auto
mode.
Setting/releasing of simplified locking for remote control
switch can be performed.
· Locking of all switches
· Locking of all switches except ON/OFF switch
Easy-to-operate
simplified locking
function
(Auto lock function)
TEMP.
[4- ]
23
/
32
[5- ]
1
/
8
3
/
4
[1- ]
13
/
16
[3- ]
9
/
32
(Front view)
(Side view)
(Rear view)
External dimension
Unit:mm[in.]
Heat
120
130
19
[ ]
46
83.5
Limiting the temperature setting range is possible.
Helps to avoid over-cooling or over-heating. Saves energy.
Helps to avoid forgetting to turn off the air conditioner.
HBC
controller
Содержание PURY-WP-YJM-A
Страница 1: ...DATA BOOK PURY WP YJM A CMB WP V G PEFY WP VMS1 E PEFY WP VMA E PFFY WP VLRMM E MODEL 3rd edition ...
Страница 3: ...Databook ...
Страница 5: ...1 2 INDOOR UNITS ...
Страница 39: ...1 36 INDOOR UNITS ...
Страница 51: ...1 48 INDOOR UNITS ...
Страница 61: ...1 58 INDOOR UNITS ...
Страница 68: ...2 1 HYBRID CITY MULTI OUTDOOR UNITS 2 OUTDOOR UNITS HYBRID CITY MULTI 2 3 ...
Страница 69: ...2 2 OUTDOOR UNITS ...
Страница 85: ...2 18 OUTDOOR UNITS ...
Страница 172: ...4 1 HYBRID CITY MULTI SYSTEM DESIGN 4 SYSTEM DESIGN SYSTEM DESIGN 4 3 ...
Страница 173: ...4 2 SYSTEM DESIGN ...