3 - 35
3. SIGNALS AND WIRING
3.12 Instructions for the 3M connector
When fabricating an encoder cable or the like, securely connect the shielded external conductor of the
cable to the ground plate as shown in this section and fix it to the connector shell.
External conductor
Sheath
External conductor
Pull back the external conductor to cover the sheath
Sheath
Core
Strip the sheath.
Screw
Screw
Ground plate
Cable