3 - 8
3. SIGNALS AND WIRING
Signal Name
Symbol Pin No.
Description
I/O Division
Reverse rotation start
ST2
9
This device is used in the incremental value command system.
When ST2-SG are shorted in the automatic operation mode,
positioning is executed once in the reverse rotation direction on the
basis of the position data set to the point table.
In jog operation mode, the servo motor rotates in the reverse
rotation direction while ST2-SG are shorted.
Reverse rotation denotes the direction in which the address is
decremented.
DI-1
Automatic/manual
selection
MDO
7
Short MDO-SG to choose the automatic operation mode, or open
them to choose the manual operation mode.
DI-1
Point table No. selection
1
DI0
5
The following table lists the point table numbers which may be
chosen by the combinations of DI0 and DI1:
(Note) Input signals
DI1
DI0
Point table No.
0
0
0 (Manual home position return)
0
1
1
1
0
2
1
1
3
Point table No. selection
2
DI1
14
Note: 0: DI1/DI0-SG open
1: DI1/DI0-SG shorted
DI-1
Rough match
CPO
4
CPO-SG are connected when the remaining command distance falls
within the parameter-set rough match output range. This signal is
not output while the base circuit is off.
Switching the servo-on connects CPO-SG.
DO-1
In position
INP
6
INP-SG are connected when the number of droop pulses is in the
preset in-position range. The in-position range can be changed using
parameter No. 6.
When the in-position range is increased, INP-SG may be kept
connected during low-speed rotation.
Switching the servo-on connects INP-SG.
DO-1
Trouble
ALM
18
ALM-SG are disconnected when power is switched off or the
protective circuit is activated to shut off the base circuit. Without
alarm, ALM-SG are connected within 1 after power on.
DO-1
Ready
RD
19
RD-SG are connected when the servo is switched on and the servo
amplifier is ready to operate.
DO-1
Override
VC
2
10 to 10V is applied to across VC-LG to limit the servo motor
speed. Apply 10[V] for 0[%] override, 0[V] for 100[%], or 10[V] for
200[%].
Analog
input
Analog torque limit
TLA
12
To use this signal, make external torque limit selection (TL) usable
with the Servo Configuration software.
Then the analog torque limit (TLA) is valid, torque is limited in the
full servo motor output torque range. Apply 0 to 10VDC across TLA-
LG. Connect the positive terminal of the power supply to TLA.
Maximum torque is generated at 10V. (Refer to (5) in Section 3.4.1.)
Resolution: 10bit
Analog
input
Shield
SD
Plate
Connect the external conductor of the shield cable.
Downloaded from
Содержание MELSERVO MR-J2 C Series
Страница 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Страница 33: ...1 16 1 FUNCTIONS AND CONFIGURATION MEMO Downloaded from ManualsNet com search engine ...
Страница 73: ...3 36 3 SIGNALS AND WIRING MEMO Downloaded from ManualsNet com search engine ...
Страница 127: ...5 18 5 PARAMETERS MEMO Downloaded from ManualsNet com search engine ...
Страница 145: ...6 18 6 SERVO CONFIGURATION SOFTWARE MEMO Downloaded from ManualsNet com search engine ...
Страница 155: ...7 10 7 DISPLAY AND OPERATION MEMO Downloaded from ManualsNet com search engine ...
Страница 189: ...8 34 8 COMMUNICATION FUNCTIONS MEMO Downloaded from ManualsNet com search engine ...
Страница 201: ...10 2 10 INSPECTION MEMO Downloaded from ManualsNet com search engine ...
Страница 211: ...11 10 11 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Страница 219: ...12 8 12 SPECIFICATIONS MEMO Downloaded from ManualsNet com search engine ...
Страница 227: ...13 8 13 CHARACTERISTICS MEMO Downloaded from ManualsNet com search engine ...