5 POSITIONING CONTROL
5.3 2 Axes Linear Interpolation Control
273
5
5.3
2 Axes Linear Interpolation Control
Linear interpolation control from the current stop position with the specified 2 axes is executed.
ABS-2 (Absolute data method) and INC-2 (Incremental data method) servo instructions are used in the 2 axes linear
interpolation control.
: Must be set,
: Set if required
*1 Only when the reference axis speed is specified
Processing details
■
Control using ABS-2 (Absolute data method)
• 2 axes linear interpolation from the current stop address (X
1
or Y
1
) based on the home position to the specified address (X
2
or Y
2
) is executed.
• The travel direction is set by the stop address (starting address) and positioning address of each axis.
Ex.
When the current stop address is (1000, 4000), and the positioning address is (10000, 2000).
Positioning data set in servo instructions
Common
Servo
instruction
Positioning
method
Number
of
control
axes
Arc
OSC
Parameter block
Others
Parameter block No.
Acceleration time
Deceleration time
Rapid Stop deceleration time
Torque limit value
Deceleration processing on stop input
Allowable error range for circular interpolation
S-curve ratio
Advanced S-curve acceleration/deceleration
Bias speed at start
Repeat condition
Program No.
Command speed (Continuous trajectory)
Skip
FIN acceleration/deceleration
WAIT-ON/OFF
Fixed position stop
Axis
Address/travel value
Command speed
Dwell time
M-code
Torque limit value
Auxiliary point
Radius
Central point
Number of pitches
Starting angle
Amplitude
Frequency
Interpolation control unit
Speed limit value
Reference axis No.
*1
Fixed position stop acceleration/deceleration time
INC-2
ABS-2
Absolute
Incremental
2
©
©
©
© © © © ©
© © ©
¨ ¨ ¨ © ©
Forward
direction
Y
1
Y
2
Y-axis travel value
Reverse
direction
Reverse
direction
Current stop address
(X
1
, Y
1
)
Positioning address
(X
2
, Y
2
)
Operation for X-axis, Y-axis linear interpolation
X-axis travel value
X
1
X
2
Forward
direction
0
*:
Indicates setting data.
Current stop address
Y-axis travel value
(4000 - 2000 = 2000)
X-axis travel value
(10000 - 1000 = 9000)
4000
2000
0