5 POSITIONING CONTROL
5.1 Basics of Positioning Control
263
5
V
Speed before speed change
Speed after re-starting
t
(2)
Re-starting
Servo program start
OFF
ON
CHGV instruction
(1)
(3)
[St.1040] Start accept flag
(R: n/Q: M2001+n)
[St.1047] Speed change accepting flag
(R: 32n/Q: M2061+n)
[Rq.1140] Stop command
(R: 32n/Q: M3200+20n)
Stop by the speed
change to speed "0"
(1) The "[St.1040] Start accept flag (
R: n/Q: M2001+n
)" remains on after stop by the speed change to "0".
(2) Re-starting by changing the speed again.
(3) However, if the "[Rq.1040] Stop command (
R: n/Q: M2001+n
)" turns off by turning on the
"[Rq.1140] Stop command (
R: 32n/Q: M3200+20n
)", re-starting is not possible even if make a speed
change again.