4 SERVO PROGRAMS FOR POSITIONING CONTROL
4.3 Positioning Data
■
Dwell time
Set the time until outputs the "[St.1061] Positioning complete (R: 32n/Q: M2401+20n)" after positioning to positioning
address.
■
M-code
Set the M-code.
Set for every point at the continuous trajectory control.
Updated at the start or specified point.
■
Torque limit value
Set the torque limit value.
The torque limit value is set in speed control (
), speed/position switching control, and continuous trajectory control.
The torque limit is performed based on the parameter block data at the start but can also be changed during operation.
Circular interpolation/Helical interpolation
Data that is set in the servo programs for starting circular interpolation and helical interpolation.
■
Auxiliary point (Absolute data method, incremental data method)
Set at the auxiliary point-specified circular interpolation, or auxiliary point-specified helical interpolation.
■
Radius (Absolute data method, incremental data method)
Set at the radius-specified circular interpolation, or radius-specified helical interpolation.
■
Central point (Absolute data method, incremental data method)
Set at the central point-specified circular interpolation, or central point-specified helical interpolation.
■
Number of pitches
Set at the helical interpolation.
OSC
Data that is set in high-speed oscillation. Refer to the high-speed oscillation for details. (
Oscillation)
• Starting angle
• Amplitude
• Frequency
Reference axis No.
Data that is set when a specified reference axis speed is set in 2 to 4 axes linear interpolation control.
Set the axis which is to be reference for positioning speed.
Positioning control
Description
Speed control (
)
Changes torque limit value during operation.
Speed/position switching control
Changes torque limit value during operation.
Continuous trajectory control
Sets torque limit value for every point. Performs the set torque limit at the specified point.