6 MANUAL CONTROL
6.2 Manual Pulse Generator Operation
■
Check of the manual pulse generator 1-pulse input magnification
The setting manual pulse generator 1-pulse input magnification checks the "1-pulse input magnification setting registers of the
manual pulse generator" of the applicable axis at leading edge of manual pulse generator enable flag. If the value is outside of
range, a warning (error code: 0988H) occurs and a value of "1" is used for the magnification.
■
Manual pulse generator smoothing magnification setting
A magnification to smooth leading edge/trailing edge of manual pulse generator operation is set. When a value outside the
range is set, a warning (error code: 098FH) occurs, and the magnification "0" is applied.
• Operation
Output speed (V1) = [Number of input pulses/ms]
[Manual pulse generator 1-pulse input magnification setting]
Travel value (L) = [Travel value per pulse]
[Number of input pulses]
[Manual pulse generator 1-pulse input magnification
setting]
• When the smoothing magnification is set, the smoothing time constant is as following formula.
Smoothing time constant (t) = [Smoothing magnifi 1]
56.8 [ms]
The smoothing time constant is within the range of 56.8 to 3408 [ms].
■
Errors when setting manual pulse operation data
Errors details at the data setting for manual pulse generator operation are shown below.
Manual pulse generator smoothing magnification setting register
Setting range
Manual pulse generator 1 (P1)
[Cd.1102] Manual pulse generator 1 smoothing magnification setting register (R: D35370/Q: D752)
0 to 59
Manual pulse generator 2 (P2)
[Cd.1103] Manual pulse generator 2 smoothing magnification setting register (R: D35371/Q: D753)
Manual pulse generator 3 (P3)
[Cd.1104] Manual pulse generator 3 smoothing magnification setting register (R: D35372/Q: D754)
Error details
Error processing
Axis setting is 4 axes or more
A warning (error code: 098EH) occurs, and a manual pulse generator operation is
executed according to valid for 3 axes from the lowest manual pulse generator
axis setting register.
All of bit is "0" for the effective axis No. of manual pulse generator axis No.
setting register.
A minor error (error code: 198FH) occurs, and a manual pulse generator operation
is not executed.
Manual pulse generator input
[Rq.1125] Manual pulse
generator 1 enable flag
(R: M30051/Q: M2051)
ON
V
V1
OFF
t
t
t
t