![Mitsubishi Electric MELSEC iQ-R16MTCPU Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r16mtcpu/melsec-iq-r16mtcpu_programming-manual_239141037.webp)
2 POSITIONING DEDICATED SIGNALS
2.1 Internal Relays
35
2
[St.1070] Home position return complete (R: 32n/Q: M2410+20n)
• This signal turns on when the home position return operation using the servo program has been completed normally.
• This signal turns off at the positioning start, JOG operation start and manual pulse generator operation start.
• If the home position return of proximity dog, dog cradle or stopper method using the servo program is executed during this
signal on, the minor error (error code: 197BH) occurs and home position return cannot start.
[St.1071] External signals FLS (R: 32n/Q: M2411+20n)
• This signal indicates the input status of the FLS signal set in the external signal parameter.
• When the setting of the external signal parameter and the state of the FLS signal are as follows, the upper stroke limit is
detected. Then, the operation in the direction in which the feed current value increases cannot be executed.
[St.1072] External signals RLS (R: 32n/Q: M2412+20n)
• This signal indicates the input status of the RLS signal set in the external signal parameter.
• When the setting of the external signal parameter and the state of the RLS signal are as follows, the lower stroke limit is
detected. Then, the operation in the direction in which the feed current value decreases cannot be executed.
[St.1073] External signals STOP (R: 32n/Q: M2413+20n)
• This signal indicates the input status of the STOP signal set in the external signal parameter.
• When the setting of the external signal parameter and the state of the STOP signal are as follows, the stop signal is
detected and the operation is stopped.
[St.1074] External signals DOG/CHANGE (R: 32n/Q: M2414+20n)
• This signal indicates the input state of the DOG signal set in the external signal parameter.
• When the setting of the external signal parameter and the state of the DOG signal are as follows, the proximity dog signal
or the speed/position switching signal is detected and the home position return operation or speed-position switching
control is performed.
[St.1075] Servo ready (R: 32n/Q: M2415+20n)
• This signal turns ON when the servo amplifiers connected to each axis are in the READY state (READY ON and Servo
ON). Refer to the following for details of the servo ON/OFF.
MELSEC iQ-R Motion controller Programming Manual (Common)
• This signal turns off in the following cases.
When the part of multiple servo amplifiers connected to the SSCNET
(/H) becomes a servo error, only an
applicable axis becomes the servo OFF state.
• When the external signal parameter "Contact" is set to "0: Normal Open" and the FLS signal is ON
• When the external signal parameter "Contact" is set to "1: Normal Close" and the FLS signal is OFF
• When the external signal parameter "Contact" is set to "0: Normal Open" and the RLS signal is ON
• When the external signal parameter "Contact" is set to "1: Normal Close" and the RLS signal is OFF
• When the external signal parameter "Contact" is set to "0: Normal Open" and the STOP signal is ON
• When the external signal parameter "Contact" is set to "1: Normal Close" and the STOP signal is OFF
• When the external signal parameter "Contact" is set to "0: Normal Open" and the state of the DOG signal is ON
• When the external signal parameter "Contact" is set to "1: Normal Close" and the state of the DOG signal is OFF
• "[Rq.1123] All axes servo ON command (R: M30042/Q: M2042)" is off
• Servo amplifier is not mounted
• Servo parameter is not set
• It is received the forced stop input from an external source
• Servo OFF by the "[Rq.1155] Servo OFF command (R: 32n/Q: M3215+20n)" ON
• Servo error occurs