![Mitsubishi Electric MELSEC iQ-R16MTCPU Скачать руководство пользователя страница 322](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r16mtcpu/melsec-iq-r16mtcpu_programming-manual_239141322.webp)
320
5 POSITIONING CONTROL
5.13 Speed Control (I)
■
Motion SFC program
The Motion SFC program for executing the servo program (No. 91) for speed control (
) is shown below.
*1 Example of the above Motion SFC program is started using the automatic start or sequence program.
SET M2042
[F10]
X0*M2415
[G10]
VF
Axis
1
Speed
3000pulse/s
[K91]
RST M3200
[F30]
END
!M2001
[G30]
SET M3200
[F20]
!X0
[G20]
Turn on all axes servo ON command.
Wait until X0 and Axis 1 servo ready turn on.
Wait until X0 turns OFF after speed control (
³
) start.
Turn on Axis 1 stop command.
Turn OFF Axis 1 stop command.
Wait until Axis 1 start accept flag turn OFF.
Speed control (
³
)
Speed control (
³
) (Forward rotation)
Axis used . . . . . . . . . Axis 1
Positioning speed . . . 3000 [pulse/s]