7 AUXILIARY AND APPLIED FUNCTIONS
7.3 Torque Limit Function
429
7
Monitoring of torque limit status
The torque limit value of each axis can be monitored with "[Md.35] Torque limit value (R: 48n/Q: D14+20n)", and the
positive/negative direction torque limit value can be monitored by setting "Positive Direction Torque Limit Value Monitor
Device" and "Negative Direction Torque Limit Value Monitor Device" in the expansion parameter of Motion control parameter.
The torque limit status of each axis can be also monitored with "[St.1076] Torque limiting (R: 32n/Q: M2416+20n)".
Operation description
*1 The torque limit value specified with servo program is clamped with the negative direction torque limit value changed by CHGT.
*2 The torque limit value is not changed so that "-1" is set as the positive direction torque limit value of CHGT.
: Positive direction torque limit value (Forward rotation (CCW) driving torque and
reverse rotation (CW) regenerative torque)
0
300.0[%]
300.0[%]
300.0[%]
40.0[%]
30.0[%]
30.0[%]
20.0[%]
40.0[%]
10.0[%]
20.0
40.0
60.0
Torque limit value [%]
t
*1
*2
[St.1040] Start accept flag
(R: n/Q: M2001+n)
Torque limit value change
request (CHGT)
Servo program start
(Torque limit value: 30[%])
Positive direction torque limit
value monitor device
Negative direction torque limit
value monitor device
[Md.35] Torque limit value
storage register
(R: 48n/Q: D14+20n)
Positive direction: 40.0[%] Negative direction: 20.0[%]
Positive direction: -1 Negative direction: 10.0[%]
: Negative direction torque limit value (Reverse rotation (CW) regenerative torque
and forward rotation (CCW) driving torque)