5 POSITIONING CONTROL
5.4 3 Axes Linear Interpolation Control
277
5
Ex.
When the current stop address is (1000, 2000, 1000), and the specified address is (4000, 8000, 4000).
■
Control using INC-3 (Incremental data method)
• Positioning control from the current stop address to the position which combined travel direction and travel value specified
with each axis is executed.
• The travel direction for each axis is set by the sign (+/ -) of the travel value for each axis, as follows:
Ex.
X-axis travel value is 10000, Y-axis travel value is 5000 and Z-axis value is 6000.
Travel direction
Description
Positive
Positioning control to forward direction (Address increase direction)
Negative
Positioning control to reverse direction (Address decrease direction)
Positioning address
(4000, 8000, 4000)
Forward
direction
Forward direction
8000
X-axis, Y-axis and Z-axis linear
interpolation operation
Current stop address
(1000, 2000, 1000)
1000
1000
4000
4000
Home position
0
2000
Forward direction
*: Indicates setting data.
Reverse
direction
Forward direction
Forward
direction
Reverse
direction
Reverse
direction
0
Forward
direction
X
1
Y
1
Z
1
Y-axis travel
value
X-axis travel
value
Z-axis
travel
value
Current stop position
Forward direction
Forward direction
0
Home position
Forward
direction
Stop position after
positioning
(12300, 6300, 8000)
X-axis travel value (10000)
Z-axis travel
value (6000)
Positioning
operation
Current stop address
(2300, 1300, 2000)
Y-axis travel
value (5000)
5000
10000
5000
6000