![Mitsubishi Electric MELSEC iQ-R16MTCPU Скачать руководство пользователя страница 377](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r16mtcpu/melsec-iq-r16mtcpu_programming-manual_239141377.webp)
5 POSITIONING CONTROL
5.20 Simultaneous Start
375
5
5.20
Simultaneous Start
Simultaneous start of the specified servo program at one start is executed.
Simultaneous start is started using the START servo program instruction.
: Must be set,
: Set if required
*1 Only when the reference axis speed is specified
*2 It changes depending on the servo program for simultaneous start
Processing details
■
Control using START instruction
• Simultaneous start of the specified servo programs is executed.
• The servo program except for the simultaneous start (START instruction) can be specified.
• Up to 3 servo programs can be specified.
• A word device can be used as the servo program number. Refer to the following for the setting range of usable devices.
MELSEC iQ-R Motion controller Programming Manual (Common)
• When the servo program number is specified using a word device, the device value can be set to start the program or not
start the program.
*1 For operating system software version "09" or earlier, 0 to 4095.
• Each axis is controlled using the specified servo program after the simultaneous start.
Setting value
Description
-1
Servo program number not specified
0 to 8191
Program number to start
Positioning data set in servo instructions
Common
Servo
instruction
Positioning
method
Number
of
control
axes
Arc
OSC
Parameter block
Others
Parameter block No.
Acceleration time
Deceleration time
Rapid Stop deceleration time
Torque limit value
Deceleration processing on stop input
Allowable error range for circular interpolation
S-curve ratio
Advanced S-curve acceleration/deceleration
Bias speed at start
Repeat condition
Program No.
Command speed (Continuous trajectory)
Skip
FIN acceleration/deceleration
WAIT-ON/OFF
Fixed position stop
Axis
Address/travel value
Command speed
Dwell time
M-code
Torque limit value
Auxiliary point
Radius
Central point
Number of pitches
Starting angle
Amplitude
Frequency
Interpolation control unit
Speed limit value
Reference axis No.
*1
Fixed position stop acceleration/deceleration time
START
*2
*2
¨
Содержание MELSEC iQ-R16MTCPU
Страница 1: ...MELSEC iQ R Motion Controller Programming Manual Positioning Control R16MTCPU R32MTCPU R64MTCPU ...
Страница 2: ......
Страница 477: ...APPENDICES Appendix 1 Processing Times of the Motion CPU 475 A MEMO ...
Страница 481: ......