Mechanical Installation
Page 78
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
7
Mechanical Installation
7.1
Important notes
Use the ARS 2320 and ARS 2340 servo drives exclusively for control cabinet installation.
Vertical installation position with the fan down and the technology slots TECH1 and TECH2 up.
Fasten the servo drive to the control cabinet plate using the mounting plate.
Installation spaces:
Keep a minimum distance of 100 mm underneath and above the servo drive to other components
to ensure sufficient ventilation.
The ARS 2320 and ARS 2340 servo drives may be installed adjacently in one switch cabinet
without a gap, proper usage and installation on a heat-dissipating rear panel provided. Please
note that excessive heating may cause premature aging and/or damaging of the servo drive. The
case of high thermal stress of the servo drives, the following installation distances (dimension A in
the following illustrations) are recommended:
ARS 2320: 95 mm (see
Figure 15
)
ARS 2340: 95 mm (see
Figure 16
)
For the devices ARS 2320W und ARS 2360W, the water cooling system is the limiting factor. Two
examples for water cooling systems are listed in
chapter 7.5
.
Содержание ARS 2320
Страница 1: ......