Electrical installation
Page 120
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
8.11.4
Cable type and configuration [X10]
We recommend using encoder connection cables in which the incremental encoder signals are twisted
in pairs and the individual pairs are shielded.
8.11.5
Connection notes [X10]
Input [X10] can be used to process incremental encoder signals and pulse direction signals like the
ones generated by control cards for stepper motors.
The input amplifier at the signal input is designed to process differential signals in accordance with the
RS422 interface standard. It may also be possible to process other signals and levels (for example 5V
single-ended or 24V
HTL
from a PLC). Please contact your distributor.
D-SUB connector
at X10
Incremental encoder input
2
3
4
5
6
7
8
1
9
Connector
housing
1
5
9
6
B# / DIR#
B / DIR
N
A / CLK
N#
GND
VCC
A# / CLK#
Male
Cable shield
(optional)
Connector housing
Incremental encoder
(e.g. ROD 426)
Figure 40:
Pin assignment: Input of the incremental encoder [X10]