Service functions and error messages
Page 149
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
Error message Meaning of the error message Measures
Main
index
Sub
index
3
Start positioning rejected: wrong
mode of operation
The change of the mode of operation could not
be performed by the position set.
4
Start positioning discarded:
homing required
Reset the optional parameterisation “homing
required”.
Perform a new homing run.
5
Rotary axis: direction of rotation
is not allowed
According to the selected mode of the rotary axis
the calculated direction of rotation is not allowed.
Check the selected mode.
9
Error at positioning start
Check speed parameters and acceleration
43
0
Limit switch:
Negative set point inhibited
The drive has left the intended motion range.
Technical defect in the system?
Check the limit switches.
1
Limit switch:
Positive set point inhibited
2
Limit switch:
Positioning suppressed
44
0
CAM table error
Check whether the index has been assigned
correctly.
Check whether there are cam plates present in
the device.
1
CAM: drive not referenced
Ensure that the drive has been homed prior to
the activation of the cam plate.
Delete the “homing necessary” option.
Ensure that a cam plate cannot be started during
a homing run.
45
0
Supply voltage cannot be
switched off
Please contact the Technical Support.
1
Supply voltage cannot be
switched on
2
Supply voltage has been
activated
47
0
Error set-up mode: timeout
expired
Check the processing of the request by the PLC.
Speed threshold too low or timeout too small?
Содержание ARS 2320