Service functions and error messages
Page 146
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
Error message Meaning of the error message Measures
Main
index
Sub
index
8
Supply power breakdown at
servo drive enable
Check the power supply.
9
Phase failure
33
0
Following error encoder
emulation
Check the settings of the incremental encoder
emulation (number of lines).
If necessary, contact the Technical Support.
34
0
No synchronisation via field bus Failure of synchronization messages from
master?
1
Field bus synchronisation error Failure of synchronization messages from
master?
Parameterization of synchronization interval too
small?
35
0
Speed protection of Linear
motor
The encoder signals are disturbed. Check the
installation for compliance with EMC
recommendations.
5
Error during the determination
of the commutation position
For this motor an improper method has been
chosen. Please contact the Technical Support.
36
0
Parameter limited
Check user parameter set.
1
Parameter not accepted
37
0
sercos:
Excessive distortion
Check the sercos wiring (for example clean the
optical fibre).
Check settings for the luminous power.
Check the baud rate.
1
sercos:
Ring not closed
Check the sercos wiring (optical fibre) for breaks.
Check the connections.
2
sercos:
MST missing twice
Check the sercos wiring (optical fibre).
Check the control system (are all of the MSTs
being transmitted?)
3
sercos:
Illegal phase requested by
master
Check the program in the sercos master
Содержание ARS 2320