Technical data
Page 52
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
4.8.3
I/O interface [X1]
Table 22:
Technical data: Digital inputs and outputs [X1]
Digital inputs/outputs
Values
Signal level
24V (8V...30V) active high, conforming with DIN EN 61131-2
Logic inputs general
DIN0
DIN1
DIN2
DIN3
Bit 0 \
Bit 1, \ Target selection for positioning
Bit 2, / 16 targets selectable from target table
Bit 3 /
DIN4
Control input power stage (enable at High)
DIN5
Servo drive enable at high signal, acknowledge error with falling edge
DIN6
Limit switch input 0
DIN7
Limit switch input 1
DIN8
Control signal Start positioning or
Homing switch for homing or saving of positions
DIN9
Control signal Start positioning or
Homing switch for homing or saving of positions
Logic outputs general
Galvanically separated, 24V (8V...30V) active high
DOUT0
Operational state
24 V, max. 100 mA
DOUT1
Freely configurable
24 V, max. 100 mA
DOUT2
Freely configurable, optional use as input DIN 10
24 V, max. 100 mA
DOUT3
Freely configurable, optional use as input DIN 11
24 V, max. 100 mA
DOUT4 [X6]
Holding brake
24 V, max. 2 A
Содержание ARS 2320