Mechanical Installation
Page 84
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
24V : 24VDC supply
REL : Relay for interrupting the driver supply
0V
: GND 24VDC supply
ERR : Signaling contact "Error on safety module"
NC1 and NC2: Response contact for driver supply
[X2
A]
R
ESO
LVER
[X3
] SAF
E
ST
AN
D
/
SU
PL
LY
24
V
[X2
B]
EN
C
O
D
ER
24V
REL
0V
ERR
NC1
NC2
[X2B]: Encoder connection
[X2A]: Resolver connection
Figure 20:
Servo drives ARS 2340 and ARS 2360W: Bottom view
Note:
The depth gauge of the water cooled devices is approximately 70 mm shorter.
7.4
Installation
The ARS 2300 servo drive has fastening straps at the top and at the bottom. Using these straps, the
servo drive has to be installed perpendicularly on a control cabinet mounting plate. The fastening
straps are part of the heat sink profile. This is why the best possible heat transfer to the control cabinet
plate has to be ensured.
Please use M6 screws for the mounting of the servo drives ARS 2320, ARS 2340, ARS 2320W, and
ARS 2360W.
Содержание ARS 2320
Страница 1: ......